![background image](http://html.mh-extra.com/html/panasonic/i-pro-extreme-series/i-pro-extreme-series_manual_277506040.webp)
SNMP MIB manual for i-PRO camera
Panasonic i-PRO Sensing Solutions Co., Ltd.
40
3.2.4.4.
Wiper, Fan, Heater, Defroster
PANA-CAM-MIB
+ panasonic(258)
| + securityProducts(5100)
| | + nwCamera(100)
| | | + camCapabilities(1)
| | | | + Wiper(14)
| | | | | + wiperNumber(1)
| | | | + FAN(16)
| | | | | + fanNumber(1)
| | | | | + FANTable(2)
| | | | | | + FANEntry(1)
| | | | | | | + fanIndex(1)
| | | | | | | + fanName(2)
| | | | | | | + fanState(3)
| | | | + Heater(17)
| | | | | + heaterNumber(1)
| | | | | + HeaterTable(2)
| | | | | | + HeaterEntry(1)
| | | | | | | + heaterIndex(1)
| | | | | | | + heaterName(2)
| | | | | | | + heaterState(3)
| | | | + Defroster(18)
| | | | | + defrosterNumber(1)
| | | | | + DefrosterTable(2)
| | | | | | + DefrosterEntry(1)
| | | | | | | + defrosterIndex(1)
| | | | | | | + defrosterName(2)
| | | | | | | + defrosterState(3)
▪
Recommended monitoring method
-
f you want to monitor the function stop status due to power cable disconnection,
monitor the items other than (1) in State of each item.
▪
When an error notification is received from the network monitoring system
-
Disabled(2)
○
The function is stopped by disconnecting the power cable. Connect the power
cable.