![background image](http://html.mh-extra.com/html/panasonic/i-pro-extreme-series/i-pro-extreme-series_manual_277506029.webp)
SNMP MIB manual for i-PRO camera
Panasonic i-PRO Sensing Solutions Co., Ltd.
29
3.2.4.7.
Temperature sensor
Only models equipped with a temperature sensor respond.
PANA-CAM-MIB
+ panasonic(258)
| + securityProducts(5100)
| | + nwCamera(100)
| | | + camCapabilities(1)
| | | | + TemperatureSensor(11)
| | | | | + TempSensorNumber(1)
| | | | | + TempSensorTable(2)
| | | | | | + TempSensorEntry(1)
| | | | | | | + tempSensorIndex(1)
| | | | | | | + tempSensorName(2)
| | | | | | | + tempSensorState(3)
| | | | | | | + tempSensorInfo(4)
TempSensorNumber
objectName
TempSensorNumber
object id
.1.3.6.1.4.1.258.5100.100.1.11.1
SYNTAX RANGE INTEGER
DESCRIPTION
Number of temperature sensors
TempSensorTable
This table allows you to check the abnormal state of the temperature sensor.
Response example:
(index) tempSensorIndex tempSensorName
tempSensorState
1
1
tempSensor1
1
2
2
tempSensor2
1
▪
Recommended monitoring method
-
If anything other than (1) responds, it is abnormal.
-
If you want to monitor the temperature sensor stop state due to power cable
disconnection
-
If you want to monitor temperature sensor abnormalities
▪
When an error notification is received from the network monitoring system
-
Disabled(2)
○
The temperature sensor is stopped due to the power cable being disconnected.
Connect the power cable.
-
Failed(4)
○
The temperature sensor is in an abnormal state