SNMP MIB manual for i-PRO camera
Panasonic i-PRO Sensing Solutions Co., Ltd.
32
3.2.4.1.
Stream settings
PANA-CAM-MIB
+ panasonic(258)
| + securityProducts(5100)
| | + nwCamera(100)
| | | + camCapabilities(1)
| | | | | + streamNumber(2)
| | | | | + StreamTable(3)
| | | | | | + StreamEntry(1)
| | | | | | | + streamIndex(1)
| | | | | | | + streamName(2)
| | | | | | | + streamTransmission(3)
| | | | | | | + streamEncodingFormat(4)
| | | | | | | + captureWidth(5)
| | | | | | | + captureHeight(6)
streamNumber
objectName
streamNumber
object id
.1.3.6.1.4.1.258.5100.100.1.12.2
SYNTAX RANGE Unsigned32
DESCRIPTION
Number of stream setting
Number of settings that can be distributed among the “Stream(n)” settings in Setup> Image /
Audio> Image settings. For example, if only stream delivery using Stream(2) and Stream(3)
settings is possible, 2 is returned.
StreamTable
For example, if stream delivery using Stream(2) and Stream(3) settings is possible, this table
responds by skipping Index1 such as
streamIndex.2 = 2
,
streamIndex.3 = 3
.
Response example:
.1.3.6.1.4.1.258.5100.100.1.12.3.1.1.2(streamIndex.2) = 2
.1.3.6.1.4.1.258.5100.100.1.12.3.1.1.3(streamIndex.3) = 3
.1.3.6.1.4.1.258.5100.100.1.12.3.1.2.2(streamName.2) = stream2
.1.3.6.1.4.1.258.5100.100.1.12.3.1.2.3(streamName.3) = stream3
:::
▪
Recommended monitoring method
-
If you want to keep a history of setting changes by the camera administrator
▪
When an error notification is received from the network monitoring system
-
Settings changed. If it is an unintended change, take action such as returning the
setting.