4.4 Function Settings
69
When an alarm has occurred, for example when the sensor cannot measure the distance
because it is too dark, the analog output can be kept on hold or set to a fixed value. The bold
table entry indicates the default setting.
Setting
Function
Digital display
Hold
Holds the analog output immediately before
the alarm.
Fixed value
The analog output depends on the setting for the
analog output (see page 66).
21.6mA for current output
+11.000V for voltage output
1.
2.
3.
Procedure
1.
2s
2.
5x
3.
4.
5.
or
to change the setting
6.
to confirm
4.4.6.2 Digital Output at Alarm
Sets the digital output behavior for when an alarm occurs.
When an alarm has occurred, for example when the sensor cannot measure the distance
because it is too dark, the digital output can be kept on hold or set to a fixed value. The bold
table entry indicates the default setting.
Setting
Function
Digital display
Hold
Holds the digital output immediately before
the alarm.
Fixed Value
Outputs a fixed value:
9.9999 (30mm type)
99.999 (50/80/120mm type)