HL-G1 User's Manual
4.4 Function Settings
71
1.
2.
3.
Procedure
1.
2s
2.
5x
3.
4.
2x
5.
The leftmost digit is selected. Press
and
together to select the next digit.
6.
to change the selected digit
7.
to confirm
4.4.7 COM Functions (Multifunction Type Only)
This function menu is available only for the multifunction type and is
used for serial communication.
4.4.7.1 Terminating Resistor Selection
Selects the terminating resistor for a sensor head connected to a host
device via RS422/485.
NOTE
Select R3 if the system is connected to other equipment via RS422.
If multiple sensor heads are connected to other equipment via RS485, set
R3 for the terminating sensor and the rest of the sensors to OFF.
If the RS422/485 communication is unstable, select R1 or R2.