background image

 
 
 

12 

 

Model

HIT Power 240S

HIT Power 235S

HIT Power 230S

VBHN240SA11

VBHN235SA11

VBHN230SA11

VBHN240SA11B

VBHN235SA11B

VBHN230SA11B

Cell Number in Series

72

72

72

Rated Power, Watts (Pmax)

240

235

230

Maximum Power Voltage (Vpm)

43.7

43.0

42.3

Maximum Power Current (Ipm)

5.51

5.48

5.45

Open Circuit Voltage (Voc)

52.4

51.8

51.2

Short Circuit Current (Isc)

5.85

5.84

5.83

Cell Type

Heterojunction

Heterojunction

Heterojunction

Maximum System Voltage (Voc)

600

600

600

Factory Installed Bypass Diodes  

3

3

3

Maximum series fuse (A)

15

15

15

Mechanical Specifications

Length, mm (inches)
Width, mm (inches)
Frame Depth, mm (inches)
Weight, kg (pounds)

35 (1.4)

15 (33.1)

Electrical Specifications

1580 (62.2)

798 (31.4)

SPECIFICATIONS  

  

 
 

Figure 2   Dimensions 

Dimensions 

All HIT Power S Models (VBHNxxxSA11VBHNxxxSA11) 

Note : A module should be installed on a mounting structure rail in accordance with the following 

Use four (4) symmetrical mounting within setting range A. 

: range A 

Front 

Side 

Backside 

Dimensions in mm 

Mount Locations 

Ground (4 places) 

Label 

Onamba 
Junction Box 

Negative 

 (-) 

Positive  
(+) 

Summary of Contents for HIT Power 240S Series

Page 1: ...is part of the Panasonic Group and is in charge of the manufacturing process for Panasonic HIT Model No HIT Power 240S VBHN240SA11 and 11B HIT Power 235S VBHN235SA11 and 11B HIT Power 230S VBHN230SA1...

Page 2: ...sed Content New Edition 2013 4 19 2nd Edition 2015 3 18 1 System Fire Class Rating 2 Trademark 3 Front cover Grounding 1 Addition of System Fire Class Rating 2 Explanation of trademark 3 According to...

Page 3: ...ss diodes Do not touch a module unnecessarily The glass surface and frames get hot There is a risk of burn CAUTIONS Use a module for its intended purpose only Do not treat the back sheet frame or fron...

Page 4: ...ons see figure 1 and below Provider UniRac Inc Part number SolarMount Clamps type Top Mounting Clamps Clamp size Mid clamp and End clamp C size Unirac Part No 302003 302101 Width 1 5 38 mm Thickness 0...

Page 5: ...ock To avoid the hazard of electric shock and sparks please connect each cable after confirming the polarity of them is correct Cable conduits should be used in locations where the wiring is inaccessi...

Page 6: ...olts star washers spilt ring lock washers flat washers and the like is used to attach a listed grounding bonding device the attachment must be made in conformance with the grounding device manufacture...

Page 7: ...his will terminate the wire For more information please refer to Instruction sheet issued by Tyco Electronics Using a Grounding Clip with bolt and nut Use Tyco Electronics 1954381 2 as grounding clip...

Page 8: ...ation use or maintenance by using this manual Panasonic assumes no responsibility for any infringement of patents or other rights of third parties which may result from use of modules No license is gr...

Page 9: ...frame and the flat washer diameter must be greater than the cup washer diameter If using a brass cup washer a flat washer must be inserted between the cup washer and module frame and the flat washer...

Page 10: ...eter 5 2mm Flat washer Stainless steel Thickness not less than 0 037 0 94 mm Diameter not less than 0 75 19 05 mm Grounding Lug Bolt Stainless steel 8 10 M5 Nut Stainless steel Copper wire Set screw S...

Page 11: ...und holes illustrated in Figure 3 1 Grounding Clip Assemblies Tyco Electronics 1954381 2 Glass Backsheet Frame Longer side Grounding hole 0 205 diameter 5 2mm Grounding Clip 8 32 Screw Stainless steel...

Page 12: ...System Voltage Voc 600 600 600 Factory Installed Bypass Diodes 3 3 3 Maximum series fuse A 15 15 15 Mechanical Specifications Length mm inches Width mm inches Frame Depth mm inches Weight kg pounds 35...