40
ECONAVI operation
An automatic operating mode with the “Air volume” is set to [Auto]. This mode is a combination of “Patrol mode”
that detects dirt in the air of the room every hour, and “Learning mode” that learns when dust is likely to be
generated in advance from the daily dirt generation patterns.
It saves power by stopping operation automatically when the air is clean. Meanwhile, the product will operate in
advance to eliminate the dirt effectively before spreading, thus reducing the operation time.
The power saving effect is different depending on the installation environment and the usage.
Patrol mode
Learning mode
The product pauses automatically when the air is
clean, and after remaining paused for 55 minutes,
“Patrol mode” (“Air volume” set to [Med]) starts for
5 minutes.
During operation, the product memorizes the time
and dirtiness level, and the next day, it will run the
preventive operation 5 minutes before the
memorized time.
(The memory is updated every day. If it is
disconnected, the previous memory is erased.)
Ɣ
While the operation is paused and in the patrol mode,
if the dirt is detected, the product will operate with the
air volume corresponding to the level of dirtiness.
Ɣ
When humidification is set, the product may operate
depending on the level of humidity in the room,
regardless of whether the air there is clean.
Functions of the ion sterilization unit (anti-fungus agent containing)
Keeps the inside of the tray clean.
Sterilization Testing trustee: Japan Food Research Laboratories Test method: Verify with the standard agar plate culture method using standard method agar.
Sterilization method: Contact with ion sterilization unit.
Target: Water in tray with ion sterilization unit deployed Test outcome: 99% or more suppression in 24 hours
[No. 15059465001-0101]
Test performed using two types of microorganism.
Anti-fungus
Testing trustee: BOKEN QUALITY EVALUATION INSTITUTE
Test method: Verify the method to prevent mold bacteria (Halo method).
Anti-fungus method: Install the anti-fungus assembly to the tray.
Target: Humidifying filter in the tray
Test outcome: Confirm that inhibited.
[No. 09006504-1]
About light sensor mode
Detecting indoor brightness with the light sensor, the product adjusts the brightness of indicators and the front
indication of control panel and adjusts the air volume, automatically.
(The initial setting is “Light sensor 1”.)
Ɣ
The brightness of the front indication in “Light sensor
mode” can be changed.
Stop operation, then press and hold
and
simultaneously.
(“Airflow” indicator is lit in order.)
Release the buttons when the brightness reaches
you want.
“Airflow” indicator display:
No Light sensor
Light sensor 2
Light sensor 1
Ɣ
The air volume does not change if the “Air volume” is
set to [Hi], [Med] or [Lo], or if the product is operating
in “Easy Housework” mode.
Light Sensor
Setting
Display
Indoor brightness
dim
dark
Light sensor 1
Control panel
All on
Half on
Front indication
Half on
Off
Light sensor 2
Control panel
All on
Half on
Front indication
Half on
No Light sensor
Control panel
All on
Front indication
Further information
VXL95M_EN-ARA.indd 40
10/15/2015 5:47:47 PM