12
Humidity indicator
nanoe™ indicator
Clean sign
ECONAVI indicator
Presence detection indicator
Check indicator
Front indication
Ŷ
Presence sensor
(P.4)
Detects and notifies the actions of people with a sign
(the indicator lit).
The sensitivity of the sensor can be changed. (P.44
Q13)
Ŷ
ECONAVI indicator
Ɣ
The indicator is lit during ECONAVI operation (P.40).
Ɣ
ECONAVI operation can be turned off. (P.44 Q16)
Ŷ
Filter replacement notification indicator
Ɣ
The replacement timing for the nanofiber HEPA
filter and deodorizing filter are notified with the
indicator lit. When the indicator turns on, it is time to
replace the nanofiber HEPA filter and deodorizing
filter, so please replace the filters.
5HSODFLQJILOWHUVĺ3
After replacing the filters, press and hold
and
simultaneously for
3 seconds to reset the product. (The indicator is
turned off.) If the product is not reset, it will stop
operating 1 week after the indicator turns on.
Ŷ
nanoe™ indicator
Ɣ
The indicator is lit when nanoe™ is generated.
(It turns on in all operating modes.)
Ɣ
nanoe™ operation can be turned off. (P.44 Q17)
Ŷ
Water supply indicator
Ɣ
If there is no more water in the tank when
humidification is set, a beeping notification sound is
emitted and the “Water supply” indicator blinks.
ĺ
Fill the tank with water. (P.16)
Ɣ
When the water supply indicator is blinking, the product
operates without any humidification.
Ŷ
Check indicator
Ɣ
When the abnormality occurs in the products, the indicator is lit.
ĺ
When the indicator is lit. (P.48 )
Ŷ
Humidity indicator
The indicators are lit even when operation is stopped.
Ɣ
For the current humidity, the general humidity level
is notified in 1% units.
The display range is from 20% to 85%.
20% or less…
turns on
85% or more…
turns on
(The humidity figure cannot be set.)
Water supply indicator
Sandstorm indicator
Presence sensor
detector
Smoke indicator
Odor indicator
Filter replacement notification indicator
The clean sign notifies how dirty the air is, and each
sign indicates the type of dirt present.
The sensitivity of the sensor can be changed.
(P.42 Q8)
Ŷ
Clean sign
(Blue): indicates the air is clean.
(Red·1): indicates the air is
slightly dirty.
(Red·3): indicates the air is
dirty.
Ŷ
Sandstorm indicator
It turns on when sand dust is detected.
Ŷ
Smoke indicator
It turns on when smoke is detected.
Ŷ
Odor indicator
It turns on when odors are detected.
* Depending on the dirt present, only the clean sign
may turn on red without any other indicator turning on.
Parts identification