![Panasonic EB-X300 Service Manual Download Page 73](http://html.mh-extra.com/html/panasonic/eb-x300/eb-x300_service-manual_261901073.webp)
– 8-11 –
8.3.7. Battery
The Analogue Baseband Processor (U201) adjusts the ADC automatically, therefore, no external adjustment is required.
The ADC value can be read, as described below, as an indication of the status of U201.
Equipment setting for battery adjustment.
NOTES :
1. Change the handset comport setting before starting. Press *#369# -> Com port -> GENIE.
2. On completion of Battery Adjustment, set the comport back to Off, otherwise the handset may malfunction.
Operation Process :
1. Set power supply to 4.2V DC and click [
ADC
] to read. Check if the value is in the range.
2. Set power supply to 3.2V DC and click [
ADC
] to read. Check if the value is in the range.
Power Supply
PC
3.8 V
Dummy Battery
Download Cable