![Panasonic EB-X300 Service Manual Download Page 69](http://html.mh-extra.com/html/panasonic/eb-x300/eb-x300_service-manual_261901069.webp)
– 8-7 –
There are two parts in this test item.
(1) TX Power Scaling Factor
1.
Select Band.
2.
Click [
READ
].
3.
Select middle channel (37 for GSM etc.),
4.
Select power level (5 for GSM, 0 for DCS+PCS).
5.
Configure test set for TX power.
6.
Click [
APPLY
] for AFRCN.
7.
Click [
APPLY
] for scaling factor.
8.
Read power level on test set.
9.
Adjust scaling factor to nominal power.
10. Copy scaling factor value to box "
5
" in the relevant table.
11. Add scaling factor value to box "
0
" to "
4
" in table.
12. Repeat (3) to (9) for DCS, PCS.
13. Copy scaling factor value to box "
0
" in the relevant table.
14. Copy scaling factor to correct location in table.
15. Click "
WRITE
" (response: NVRAM WRITE ).
1
11
3
10
6
4
7
2
15
9