![Panasonic EB-X300 Service Manual Download Page 62](http://html.mh-extra.com/html/panasonic/eb-x300/eb-x300_service-manual_261901062.webp)
– 7-4 –
7.4. Test Equipment Setup
7.4.1. Equipment Required
COMPLETE UNIT TEST SETUP
PCB TEST SETUP
Figure 7.6. : Test Connection Diagram
IMPORTANT NOTE
To allow accurate measurement of the complete unit the test equipment must be connected as shown,
To test the handheld unit, the following equipment is required.
1. PCB Repair Jig
2. Power Cable
3. Download Cable
4. RF Cable
5. 12 V power supply
6. Personal computer with RS232 interface and running Microsoft Windows
®
95, 98, XP or 2000
7. GSM test station
8. EB-X300 Service software
The EB-X300 Service software should be installed onto the main drive of the personal computer.
The RF cable is connected to the GSM test station via a suitable adaptor. The 3.8 V supply is connected to the RF Adaptor and
PCB Repair Jig using the power cable.
NOTE:
A suitable test SIM card compatible with the GSM test station will be required.
GSM
Tester
GSM
Tester
3.8V DC
Power
Supply
3.8V DC
Power
Supply
PC
PC
Power Cable
Power Cable
Download Cable
Download Cable
RF Cable