Panasonic Digital Business System - Programming Manual
April 1997
Issue 15
86
AC15 flash output timer
CPC-EX 1.0
[AC15 FLASH OUT]
FF2-2#-(1-3)#-16#-(0-15)#
(1-3)#
(0-15)#
Private Circuit trunk group
0#: No timer
1#: 50 msec
2#: 100 msec
3#: 150 msec
4#: 200 msec
5#: 300 msec
6#: 400 msec
7#: 500 msec
8#: 700 msec
9#: 1000 msec
10#: 1200 msec
11#: 1500 msec
12#: 2000 msec
13#: 2500 msec
14#: 3000 msec
15#: 3500msec
This sets the flash time for private line use.
AC15 flash detect timer
CPC-EX 1.0
[AC15 FLASH DET]
FF2-2#-(1-3)#-17#-(0-15)#
(1-3)#
(0-15)#
Private Circuit trunk group
0#: 100 msec
1#: 120 msec
2#: 150 msec
3#: 170 msec
4#: 200 msec
5#: 230 msec
6#: 270 msec
7#: 700 msec
8#: 800 msec
9#: 900 msec
10#: 1000 msec
11#: 1100 msec
12#: 1200 msec
13#: 1300 msec
14#: 1400 msec
15#: 1500 msec
This sets the duration of received flash signals. A release signal with a duration less than the
setting here will be seen as a flash