14.1.5.
To remove the Cross Flow Fan and Indoor Fan Motor
• Remove the screw at the Cross Flow Fan. (Fig. 7)
Reminder :-
To reinstall the Fan Motor, please adjust the connector
location is positioned 45
°
with Fan Motor before fixing
Control Board Casing. (Fig. 7)
• Remove the Bearing. (Fig. 8)
• Remove the screws at the left of the Evaporator. (Fig. 8)
• Push up the Evaporator and pull out the Cross Flow Fan
from shaft. By then, Fan Motor can be taken out. (Fig. 9)