Indoor Unit
Outdoor Unit
Test conditions
1. Cooling: Indoor Dry Bulb Temp. (°C) 27
Outdoor Dry Bulb Temp. (°C) 35
Wet Bulb Temp. (°C) 19
Wet Bulb Temp. (°C) 24
Heating: Indoor Dry Bulb Temp. (°C) 20
Outdoor Dry Bulb Temp. (°C) 7
Wet Bulb Temp. (°C) 12 (MAX)
Wet Bulb Temp. (°C) 6
2. Standard piping length: 7.5m (Includes Indoor Unit piping length).
Model
CS-UE9HKE
CU-UE9HKE
CS-UE12HKE
CU-UE12HKE
COOL
HEAT
COOL
HEAT
Single, 230V, 50Hz
Single, 230V, 50Hz
Power/Current
[W]
800
870
1060
1170
[A]
3.50
3.90
4.70
5.20
Refrigerant
[k
g
]
R410A
0.78
R410A
0.97
Cooling Capacity
[kW]
2.60
3.50
Heating Capacity
[kW]
3.30
4.25
Noise Level
JIS C 9612
[<70 dB(A)]
[dB(A)]
42
42
42
42
Conditions
1m Distance
Max. cooling/
heating
operation
47
48
48
50
Sound power
level
[dB(A)]
53
53
53
53
60
61
61
63
Air Circulation
[m
3
/min.]
11.6
12.2
11.7
12.4
Product Weight
[k
g
]
8.5
8.5
28
30
Dimensions (L × W × H)
[mm]
799×183×280
799×183×280
780×289×540
780×289×540
k
g
produCt SpeCifiCation
produCt SpeCifiCation
F566018_EN.indd 56
2008-2-18 9:43:26