31
11. Operation
Control
11.1 Basic Function
Inverter control, which equipped with a microcomputer in determining the most suitable operation mode as time
passes, automatically adjusts output power for maximum comfort always. In order to achieve the suitable operation
mode, the microcomputer maintains the set temperature by measuring the temperature of the environment and
performing temperature shifting. The compressor at outdoor unit is operating following the frequency instructed by
the microcomputer at indoor unit that judging the condition according to internal setting temperature and intake air
temperature.
11.1.1 Internal
Setting
Temperature
Once the operation starts, remote control setting temperature will be taken as base value for temperature shifting
processes. These shifting processes are depending on the air conditioner settings and the operation environment.
The final shifted value will be used as internal setting temperature and it is updated continuously whenever the
electrical power is supplied to the unit.
11.1.2 Cooling
Operation
11.1.2.1 Thermostat
control
•
Compressor is OFF when intake Air Temperature - Internal Setting Temperature < -0.5°C.
•
Compressor is ON after waiting for 3 minutes, if the Intake Temperature - Internal Setting Temperature >
Compressor OFF point.
11.1.3 Soft Dry Operation
11.1.3.1 Thermostat
control
•
Compressor is OFF when Intake Temperature - Internal Setting Temperature < -1.0°C.
•
Compressor is ON after waiting for 3 minutes, if the Intake Air Temperature - Internal Setting Temperature >
Compressor OFF point.
11.1.3.2 Automatic
Operation
•
This mode can be set using remote control and the operation is decided by indoor intake air temperature.
•
During operation mode judgment at the beginning of the Auto Mode operation, indoor fan motor (with speed of
Lo-) is running for 30 seconds to detect the indoor intake air temperature.
•
The operation mode is decided based on below chart.
•
After the operation mode is decided, the unit operation will follow the respective operation mode control.
Remote Control Setting Temperature
16°C ~ 30°C
Indoor Air Temperature Shifting
Outdoor Air Temperature Shifting
Powerful Mode Shifting
Setting Temperature Limit Checking
(Min: 16°C; Max: 33°C)
Internal Setting Temperature
Cooling
operation
Soft Dry
operation
Indoor intake
Air Temp
23°C
Summary of Contents for CS-PS9JKT
Page 7: ...7 3 Location of Controls and Components 3 1 Indoor Unit 3 2 Outdoor Unit 3 3 Remote Control...
Page 8: ...8 4 Dimensions 4 1 Indoor Unit...
Page 10: ...10 5 Refrigeration Cycle Diagram...
Page 11: ...11 6 Block Diagram 6 1 CS PS9JKT CU PS9JKT...
Page 12: ...12 6 2 CS PS12JKT CU PS12JKT...
Page 13: ...13 7 Wiring Connection Diagram 7 1 Indoor Unit...
Page 14: ...14 7 2 Outdoor Unit 7 2 1 CU PS9JKT...
Page 15: ...15 7 2 2 CU PS12JKT...
Page 16: ...16 8 Electronic Circuit Diagram 8 1 Indoor Unit...
Page 17: ...17 8 2 Outdoor Unit 8 2 1 CU PS9JKT...
Page 18: ...18 8 2 2 CU PS12JKT...
Page 21: ...21 9 2 Outdoor Unit 9 3 Main Printed Circuit Board 9 3 1 CU PS9JKT...
Page 22: ...22...
Page 23: ...23 9 3 2 CU PS12JKT...