11.4.4.
Connect The Cable To The Outdoor Unit
(FOR DETAIL REFER TO WIRING DIAGRAM AT UNIT)
1. Remove the control board cover from the unit by loosening the screw.
2. Connecting cable between indoor unit and outdoor unit shall be approved polychloroprene sheathed 4 x 2.5 mm
2
flexible
cord, type designation 245 IEC 57 or heavier cord.
3. Secure the cable onto the control board with the holder
(clamper).
4. Cable connection to the power supply through knife
switch (Disconnecting means).
• Connect the approved polychloroprene sheathed power
supply cable (3 × 4.0 mm
2
), type designation 245 IEC 57
or heavier cord to the terminal board, and connect the
other end of the cable to knife switch (Disconnecting
means).
5. Select required direction and apply protective bushing provided in accessories to protect cables from sharp edges.
6. Once all wiring work has been completed, tie the wires and cords together with the binding strap so that they do not touch
other parts such as the compressor and pipes.
7. For wire stripping and connection requirement, refer to instruction of indoor unit.
Check that the wires do not touch the compressor, etc.
Note
: Knife switch (Disconnecting means) should have minimum 3.0 mm contact gap.
• Secure the cable onto the control board with the holder (clamper).
This equipment must be properly earthed.
• Earth wire shall be Yellow/Green (Y/G) in colour and longer than other AC wires for safety reason.
11.4.5.
Pipe Insulation
1. Please carry out insulation at pipe connection portion as mentioned in Indoor/Outdoor Unit Installation Diagram. Please wrap
the insulated piping end to prevent water from going inside the piping.
2. If drain hose or connecting piping is in the room (where dew may form), please increase the insulation by using POLY-E
FOAM with thickness 6mm or above.
Summary of Contents for CS-PC30JKF
Page 9: ...9 5 Dimensions 5 1 Indoor Unit Remote Control ...
Page 10: ...10 5 2 Outdoor Unit 5 2 1 CU PC30JKF ...
Page 11: ...11 5 2 2 CU PC36JKF ...
Page 12: ...12 6 Refrigeration Cycle Diagram 6 1 CS PC30JKF CU PC30JKF ...
Page 13: ...13 6 2 CS PC36JKF CU PC36JKF ...
Page 14: ...14 7 Block Diagram ...
Page 15: ...15 8 Wiring Connection Diagram 8 1 Indoor Unit 8 1 1 CS PC30JKF CS PC36JKF ...
Page 18: ...18 9 Electronic Circuit Diagram 9 1 Indoor Unit ...
Page 19: ...19 9 2 Outdoor Unit 9 2 1 CU PC30JKF ...
Page 20: ...20 9 2 2 CU PC36JKF ...
Page 21: ...21 10 Printed Circuit Board 10 1 Indoor Unit 10 1 1 Main Printed Circuit Board ...
Page 22: ...22 10 1 2 Power Printed Circuit Board 10 1 3 Indicator Printed Circuit Board ...
Page 23: ...23 10 2 Outdoor Unit 10 2 1 Main Printed Circuit Board 10 2 1 1 CU PC30JKF ...
Page 24: ...24 10 2 1 2 CU PC36JKF ...
Page 47: ...47 16 1 3 To remove discharge grille ...
Page 48: ...48 16 1 4 To remove control board 16 1 5 To remove cross flow fan and indoor fan motor ...
Page 49: ...49 ...
Page 50: ...50 17 Technical Data 17 1 Thermostat Characteristics Cooling Soft Dry ...
Page 51: ...51 17 2 Operation Characteristics 17 2 1 CS PC30JKF CU PC30JKF ...
Page 52: ...52 ...
Page 53: ...53 17 2 2 CS PC36JKF CU PC36JKF ...
Page 54: ...54 ...
Page 57: ...57 17 5 Sound Data 17 5 1 CS PC30JKF CU PC30JKF 17 5 2 CS PC36JKF CU PC36JKF ...
Page 62: ...62 18 2 Outdoor Unit 18 2 1 CU PC30JKF ...
Page 65: ...65 18 2 2 CU PC36JKF ...
Page 66: ...66 ...