30
11.4. Outdoor Unit
11.4.1.
Install The Outdoor Unit
• After selecting the best location, start installation according to Indoor/Outdoor Unit Installation Diagram.
1. If installing the unit to a concrete base or other solid base,
use M10 or W3/8 bolts and nuts to secure the unit, and
ensure that the unit is fully upright and level.
(The anchor bolt positions are shown in the diagram at
the right side.)
In particular, install the unit at a distance from the
neighbouring building which conforms to regulations
specified by local noise emission regulation standards.
2. Do not install the outdoor unit to the building’s roof.
3. If there is a possibility that vibration may be transmitted to
the rooms of the building, place rubber insulation
between the unit and the installation surface.
11.4.2.
Connecting The Piping
11.4.2.1. Connecting The Piping To Indoor Unit
Please make flare after inserting flare nut (locate at joint portion of tube assembly) onto the copper pipe (in case of using long
piping).
Connect the piping
• Connect tube ass’y as shown in the picture. (PC36 only)
• Align the center of piping and sufficiently tighten the flare nut with fingers.
• Further tighten the flare nut with torque wrench in specified torque as stated in the table.
CAUTION
Do not over tighten, over tightening cause gas leakage.
Model
Piping size (Torque)
Gas
Liquid
PC30
5/8” [65 N m]
3/8” [42 N m]
PC36
3/4” [100 N m]
3/8” [42 N m]
Summary of Contents for CS-PC30JKF
Page 9: ...9 5 Dimensions 5 1 Indoor Unit Remote Control ...
Page 10: ...10 5 2 Outdoor Unit 5 2 1 CU PC30JKF ...
Page 11: ...11 5 2 2 CU PC36JKF ...
Page 12: ...12 6 Refrigeration Cycle Diagram 6 1 CS PC30JKF CU PC30JKF ...
Page 13: ...13 6 2 CS PC36JKF CU PC36JKF ...
Page 14: ...14 7 Block Diagram ...
Page 15: ...15 8 Wiring Connection Diagram 8 1 Indoor Unit 8 1 1 CS PC30JKF CS PC36JKF ...
Page 18: ...18 9 Electronic Circuit Diagram 9 1 Indoor Unit ...
Page 19: ...19 9 2 Outdoor Unit 9 2 1 CU PC30JKF ...
Page 20: ...20 9 2 2 CU PC36JKF ...
Page 21: ...21 10 Printed Circuit Board 10 1 Indoor Unit 10 1 1 Main Printed Circuit Board ...
Page 22: ...22 10 1 2 Power Printed Circuit Board 10 1 3 Indicator Printed Circuit Board ...
Page 23: ...23 10 2 Outdoor Unit 10 2 1 Main Printed Circuit Board 10 2 1 1 CU PC30JKF ...
Page 24: ...24 10 2 1 2 CU PC36JKF ...
Page 47: ...47 16 1 3 To remove discharge grille ...
Page 48: ...48 16 1 4 To remove control board 16 1 5 To remove cross flow fan and indoor fan motor ...
Page 49: ...49 ...
Page 50: ...50 17 Technical Data 17 1 Thermostat Characteristics Cooling Soft Dry ...
Page 51: ...51 17 2 Operation Characteristics 17 2 1 CS PC30JKF CU PC30JKF ...
Page 52: ...52 ...
Page 53: ...53 17 2 2 CS PC36JKF CU PC36JKF ...
Page 54: ...54 ...
Page 57: ...57 17 5 Sound Data 17 5 1 CS PC30JKF CU PC30JKF 17 5 2 CS PC36JKF CU PC36JKF ...
Page 62: ...62 18 2 Outdoor Unit 18 2 1 CU PC30JKF ...
Page 65: ...65 18 2 2 CU PC36JKF ...
Page 66: ...66 ...