After AUTO OFF/ON button is pressed, the 20 seconds counter for Remote Control Receiving Sound OFF/ON mode is
restarted.
14.2. Remote Control Button
14.2.1.
SET
• To change the type of remote control transmission signal (there are totally four types of transmission codes).
- Modify the jumper (back of PCB) & connector (front of PCB) at remote control PCB.
- Press with pointer for more than 10 seconds.
- Face the transmitter towards indoor unit receiver and press the timer SET button (to send the signal) or if the timer SET
button is not pressed for 30 seconds, the setting mode is cancelled.
- Press timer CANCEL button to exit the setting mode.
14.2.2.
CLOCK
• To change the remote control’s clock-hour and minute.
- Press once to enter the clock setting mode.
- Use timer increment button timer decrement button to change the time.
- Press once again to exit the setting mode.
• To change the time format (24 hours & 12 hours timer display).
- Press for more than 5 seconds.
14.2.3.
RESET
• To clear and restore the remote control setting to factory default.
- Press for once to clear the memory.
14.2.4.
TIMER “ ”
• Press continuously for 5 seconds, LED intensity for Remote Control dimmer code is transmitted.
• Above condition will not happen when Timer is set.
14.2.5.
TIMER “ ”
• Press continuously for 10 seconds, set the operation and display changes as Celsius or Fahrenheit.
• Above condition will not happen when Timer is set.
Summary of Contents for CS-PC30JKF
Page 9: ...9 5 Dimensions 5 1 Indoor Unit Remote Control ...
Page 10: ...10 5 2 Outdoor Unit 5 2 1 CU PC30JKF ...
Page 11: ...11 5 2 2 CU PC36JKF ...
Page 12: ...12 6 Refrigeration Cycle Diagram 6 1 CS PC30JKF CU PC30JKF ...
Page 13: ...13 6 2 CS PC36JKF CU PC36JKF ...
Page 14: ...14 7 Block Diagram ...
Page 15: ...15 8 Wiring Connection Diagram 8 1 Indoor Unit 8 1 1 CS PC30JKF CS PC36JKF ...
Page 18: ...18 9 Electronic Circuit Diagram 9 1 Indoor Unit ...
Page 19: ...19 9 2 Outdoor Unit 9 2 1 CU PC30JKF ...
Page 20: ...20 9 2 2 CU PC36JKF ...
Page 21: ...21 10 Printed Circuit Board 10 1 Indoor Unit 10 1 1 Main Printed Circuit Board ...
Page 22: ...22 10 1 2 Power Printed Circuit Board 10 1 3 Indicator Printed Circuit Board ...
Page 23: ...23 10 2 Outdoor Unit 10 2 1 Main Printed Circuit Board 10 2 1 1 CU PC30JKF ...
Page 24: ...24 10 2 1 2 CU PC36JKF ...
Page 47: ...47 16 1 3 To remove discharge grille ...
Page 48: ...48 16 1 4 To remove control board 16 1 5 To remove cross flow fan and indoor fan motor ...
Page 49: ...49 ...
Page 50: ...50 17 Technical Data 17 1 Thermostat Characteristics Cooling Soft Dry ...
Page 51: ...51 17 2 Operation Characteristics 17 2 1 CS PC30JKF CU PC30JKF ...
Page 52: ...52 ...
Page 53: ...53 17 2 2 CS PC36JKF CU PC36JKF ...
Page 54: ...54 ...
Page 57: ...57 17 5 Sound Data 17 5 1 CS PC30JKF CU PC30JKF 17 5 2 CS PC36JKF CU PC36JKF ...
Page 62: ...62 18 2 Outdoor Unit 18 2 1 CU PC30JKF ...
Page 65: ...65 18 2 2 CU PC36JKF ...
Page 66: ...66 ...