CAUTION
WARNING
20. After completion of installation or service, confirm there is no leakage or refrigerant gas. It may generate toxic gas when the refrigerant
contacts with fire.
21. Ventilate if there is refrigerant gas leakage during operation. It may cause toxic gas when refrigerant contacts with fire.
22. Do not insert your fingers or other objects into the unit, high speed rotating fan may cause injury.
23. Must not use other parts except original parts described in catalog and manual.
1. Do not install the unit at place where leakage of flammable gas may occur. In case gas leaks and accumulates at surrounding of the
unit, it may cause fire.
2. Carry out drainage piping as mentioned in installation instructions. If drainage is not perfect, water may enter the room and damage
the furniture.
3. Tighten the flare nut with torque wrench according to specified method. If the flare nut is over-tightened, after a long period, the flare
may break and cause refrigerant gas leakage.
4. Do not touch outdoor unit air inlet and aluminium fin. It may cause injury.
5. Select an installation location which is easy for maintenance.
6. Pb free solder has a higher melting point than standard solder; typically the melting point is 50°F – 70°F (30°C – 40°C) higher. Please use
a high temperature solder iron. In case of the soldering iron with temperature control, please set it to 700 ± 20°F (370 ± 10°C).
Pb free solder will tend to splash when heated too high (about 1100°F / 600°C).
7. Power supply connection to the air conditioner. Connect the power supply cord of the air conditioner to the mains using one of the following
methods.
Power supply point shall be the place where there is ease for access for the power disconnection in case of emergency. In some countries,
permanent connection of this room air conditioner to the power supply is prohibited.
i. Power supply connection to the receptacle using a power plug.
Use an approved 15/16A (1.0~1.5HP) or 16A (2.0HP) or 20A (2.5HP) power
plug with earth pin for the connection to the socket.
ii. Power supply connection to a circuit breaker for the permanent component.
Use an approved 15/16A (1.0~1.5HP) or 20A (2.5HP) circuit
breaker for the permanent connection. It must be a double pole switch with a minimum 3.0 mm contact gap.
8. Do not release refrigerant during piping work for installation, servicing, reinstallation and during repairing a refrigerant parts.
Take care of the liquid refrigerant, it may cause frostbite
9. Installation or servicing work: It may need two people to carry out the installation or servicing work.
10. Do not install this appliance in a laundry room or other location where water may drip from the ceiling, etc.
11. Do not sit or step on the unit, you may fall down accidentally.
12. Do not touch the sharp aluminium fin, sharp parts may cause injury.
Summary of Contents for CS-PC30JKF
Page 9: ...9 5 Dimensions 5 1 Indoor Unit Remote Control ...
Page 10: ...10 5 2 Outdoor Unit 5 2 1 CU PC30JKF ...
Page 11: ...11 5 2 2 CU PC36JKF ...
Page 12: ...12 6 Refrigeration Cycle Diagram 6 1 CS PC30JKF CU PC30JKF ...
Page 13: ...13 6 2 CS PC36JKF CU PC36JKF ...
Page 14: ...14 7 Block Diagram ...
Page 15: ...15 8 Wiring Connection Diagram 8 1 Indoor Unit 8 1 1 CS PC30JKF CS PC36JKF ...
Page 18: ...18 9 Electronic Circuit Diagram 9 1 Indoor Unit ...
Page 19: ...19 9 2 Outdoor Unit 9 2 1 CU PC30JKF ...
Page 20: ...20 9 2 2 CU PC36JKF ...
Page 21: ...21 10 Printed Circuit Board 10 1 Indoor Unit 10 1 1 Main Printed Circuit Board ...
Page 22: ...22 10 1 2 Power Printed Circuit Board 10 1 3 Indicator Printed Circuit Board ...
Page 23: ...23 10 2 Outdoor Unit 10 2 1 Main Printed Circuit Board 10 2 1 1 CU PC30JKF ...
Page 24: ...24 10 2 1 2 CU PC36JKF ...
Page 47: ...47 16 1 3 To remove discharge grille ...
Page 48: ...48 16 1 4 To remove control board 16 1 5 To remove cross flow fan and indoor fan motor ...
Page 49: ...49 ...
Page 50: ...50 17 Technical Data 17 1 Thermostat Characteristics Cooling Soft Dry ...
Page 51: ...51 17 2 Operation Characteristics 17 2 1 CS PC30JKF CU PC30JKF ...
Page 52: ...52 ...
Page 53: ...53 17 2 2 CS PC36JKF CU PC36JKF ...
Page 54: ...54 ...
Page 57: ...57 17 5 Sound Data 17 5 1 CS PC30JKF CU PC30JKF 17 5 2 CS PC36JKF CU PC36JKF ...
Page 62: ...62 18 2 Outdoor Unit 18 2 1 CU PC30JKF ...
Page 65: ...65 18 2 2 CU PC36JKF ...
Page 66: ...66 ...