
15.
Power Monitor Display
16.
Remote Control Signal Receiving Sound ON/OFF
17.
Indoor Power Relay Control
Power Monitor LED lights on when the compressor is in operation. The number of the LED lights on is in accordance to the
compressor operating frequency.
Model
Display
A
A, B
A, B, C
A, B, C, D
A, B, C, D, E
Cooling & Soft Dry
Indication Frequency
15 ~ 26
31 ~ 33
36 ~ 40
43 ~ 46
51 ~ 64
(Hz)
CS-G95KE
Heating Indication
Frequency (Hz)
15 ~ 26
31 ~ 40
43 ~ 58
63 ~ 64
71 ~ 99
Cooling & Soft Dry
Indication Frequency
15 ~ 27
31 ~ 36
44 ~ 49
58 ~ 64
71 ~ 92
CS-G125KE
(Hz)
Heating Indication
Frequency (Hz)
15 ~ 27
31 ~ 44
58 ~ 79
83 ~ 86
91 ~ 115
•
Press the Auto button (at indoor unit) for 16 seconds or < 21 seconds. “Beep” “beep” “beep” “beep” will be heard at 16th second.
Remove the back cover of Remote Control, short the diagnosis (
) terminals at the back of remote control to switch to
Remote Control signal receiving sound ON/OFF mode. One “beep” will be heard*. Then, press the Auto button once again,
“beep” sound will be heard. The Remote Control signal receiving sound has been turned off.
•
Repeat the above procedure or reset the main power supply to switch on the remote control signal receiving sound.
* If “beep” “beep” sound is heard and “E1” or “E2” is displayed, the setting has been switched to H14 diagnosis mode.
Refer Servicing Information for more details.
•
The power relay turns on when one of the indoor LED lights on.
•
The power relay turns off when all of the indoor LEDs lights off.
•
When the air conditioner is stopped during operation, the power relay stays ON for 3 minutes.
•
The power relay will turn off if a sudden power failure occurs
0.05 second. The power relay will turn on again after 3-4 minutes
(Refer AUTO RESTART CONTROL). It will start with the previous operation condition before the power failure.
41
CS-G95KE CU-G95KE / CS-G125KE CU-G125KE
Summary of Contents for CS-G125KE CU-G125KE
Page 12: ...4 Dimensions 12 S G95KE CU G95KE CS G125KE CU G125KE ...
Page 13: ...13 CS G95KE CU G95KE CS G125KE CU G125KE ...
Page 14: ...5 Refrigeration Cycle Diagram 14 S G95KE CU G95KE CS G125KE CU G125KE ...
Page 15: ...6 Block Diagram 15 CS G95KE CU G95KE CS G125KE CU G125KE ...
Page 24: ... ii When indoor fan speed is lower than Medium 24 S G95KE CU G95KE CS G125KE CU G125KE ...
Page 94: ...12 Technical Data 94 S G95KE CU G95KE CS G125KE CU G125KE ...
Page 95: ...95 CS G95KE CU G95KE CS G125KE CU G125KE ...
Page 109: ...109 CS G95KE CU G95KE CS G125KE CU G125KE ...
Page 112: ...18 1 PRINT PATTERN INDOOR UNIT PRINTED CIRCUIT BOARD 112 S G95KE CU G95KE CS G125KE CU G125KE ...
Page 114: ...114 S G95KE CU G95KE CS G125KE CU G125KE MACC Printed in Malaysia ...