B. Deodorizing Control
•
This control is available during automatic fan speed for Cooling and Soft Dry Operation. It is not available during anti-
freezing control.
•
When the compressor is in operation, the deodorizing status starts from 1
→
2
→
3.
•
When the compressor stops operation, the deodorizing status starts from 4
→
5
→
6
→
7.
•
If the compressor still stops operation after 3 minutes, the deodorizing status will start from 6.
C. Sensible Heat Control
•
This control is to improve the feeling in high fan speed during low operation frequency. When the operation frequency is less
than 33Hz (CU-G95KE) or 36Hz (CU-G125KE), the fan speed will reduce. When the operation frequency is increased to
40Hz (CU-G95KE) or 49Hz (CU-G125KE) continuously for 5 minutes, the fan speed will resume to normal condition.
20
S-G95KE CU-G95KE / CS-G125KE CU-G125KE