82
17.2 Sensible Capacity Chart
CU-CE9NKE
Outdoor Temp. (°C)
230V
30 35 40 46
Indoor wet
bulb temp.
TC SHC IP TC SHC IP TC SHC IP TC SHC IP
17.0°C 2.48 1.88 0.50 2.32 1.80 0.54 2.16 1.73 0.57 1.96 1.65 0.62
19.0°C
2.50
0.55
19.5°C 2.72 1.97 0.51 2.55 1.89 0.55 2.37 1.82 0.59 2.15 1.73 0.63
22.0°C 2.97 2.04 0.52 2.77 1.96 0.56 2.58 1.89 0.60 2.35 1.81 0.64
CU-CE12NKE
Outdoor Temp. (°C)
230V
30 35 40 46
Indoor wet
bulb temp.
TC SHC IP TC SHC IP TC SHC IP TC SHC IP
17.0°C 3.47 2.63 0.87 3.24 2.52 0.94 3.02 2.43 1.00 2.74 2.30 1.08
19.0°C
3.50
0.95
19.5°C 3.81 2.76 0.89 3.56 2.65 0.95 3.31 2.55 1.02 3.01 2.43 1.10
22.0°C 4.15 2.86 0.90 3.88 2.75 0.97 3.61 2.65 1.04 3.28 2.53 1.12
TC - Total Cooling Capacity (kW)
SHC - Sensible Heat Capacity (kW)
IP - Input Power (kW)
Indoor 27°C/19°C
Outdoor 35°C/24°C
Summary of Contents for CS-CE12NKE
Page 12: ...12 4 Location of Controls and Components 4 1 Indoor Unit 4 2 Outdoor Unit 4 3 Remote Control ...
Page 13: ...13 5 Dimensions 5 1 Indoor Unit ...
Page 14: ...14 5 2 Outdoor Unit ...
Page 15: ...15 6 Refrigeration Cycle Diagram ...
Page 16: ...16 7 Block Diagram ...
Page 17: ...17 8 Wiring Connection Diagram 8 1 Indoor Unit ...
Page 18: ...18 8 2 Outdoor Unit ...
Page 19: ...19 9 Electronic Circuit Diagram 9 1 Indoor Unit ...
Page 20: ...20 9 2 Outdoor Unit ...
Page 22: ...22 10 2 Outdoor Unit ...
Page 45: ...45 15 3 Error Codes Table ...
Page 46: ...46 ...
Page 74: ...74 17 Technical Data 17 1 Operation Characteristics 17 1 1 CU CE9NKE ...
Page 75: ...75 ...
Page 76: ...76 ...
Page 77: ...77 ...
Page 78: ...78 17 1 2 CU CE12NKE ...
Page 79: ...79 ...
Page 80: ...80 ...
Page 81: ...81 ...