64
o
nanoe-G breakdown error
Judgment
method
•
Hi-feedback voltage (at microcontroller) supplied to the nanoe-G system when nanoe-G operation is
OFF; nanoe-G breakdown error show immediately.
•
It is due to indoor PCB or nanoe-G high voltage power supply damage.
•
Operations except nanoe-G continue. Both Timer indicator and nanoe-G indicator blink.
Troubleshooting
method
•
Press nanoe-G button or OFF/ON button to stop the operation.
•
Change nanoe-G high voltage power supply or main PCB.
•
When Lo-feedback voltage supplied to nanoe-G system during nanoe-G operation ON, nanoe-G
indicator and Timer indicator stop blinking.
13.14 In-filter Deactivation Operation
•
This operation helps to deactivate virus and bacteria on filter after the unit turned off using nanoe-G generator.
•
In-filter deactivation start condition
o
nanoe-G is ON before the unit is turned off either by OFF/ON button or OFF Timer.
o
Elapsed time from previous in-filter deactivation operation is more than 24hrs.
o
Unit operation time before unit is turned off is more than 2 hours or accumulated unit operation time achieves
4hrs if unit operation time less than 2hours.
•
In-filter deactivation stop condition
o
The unit is turned on.
o
nanoe-G generator operation time during in-filter deactivation operation has achieved 120 minutes.
o
The unit received disable signal from remote control.
o
Nanoe-G abnormality occurs.
•
Control
contents:
o
When the unit operate in Cool or Dry mode before turned off.
1. The unit will operate fan operation, fan motor will operate at 500rpm for 30 minutes then stop.
2. During fan operation, horizontal vane will fixed at 115° for 30 minutes then close.
3. After 30 minutes the unit will continue with common control.
o
Common
control.
- nanoe-G generator will operate for 120 minutes.
•
Timer
control
o
When ON Timer activates during in filter deactivation operation, in-filter deactivation operation stops.
o
When OFF Timer activates during in filter deactivation operation, in-filter operation will continue.
•
Indicator
o
nanoe-G
indicator
ON.
o
Power indicator OFF.
•
Enable or disable selection
o
Press NANOE-G button continuously for 5 seconds to disable or enable in-filter deactivation operation.
•
Remote control receiving sound
o
Enable in-filter deactivation operation : Beep
o
Disable in-filter deactivation operation : Long beep
•
Power
failure
o
During in-filter operation, if power failure occurs, after power resumes in-filter deactivation operation will not
resume.
Summary of Contents for CS-C12PKV
Page 12: ...12 4 Location of Controls and Components 4 1 Indoor Unit 4 2 Outdoor Unit 4 3 Remote Control ...
Page 13: ...13 5 Dimensions 5 1 Indoor Unit 5 1 1 CS C9PKV CS C12PKV ...
Page 14: ...14 5 1 2 CS C18PKV CS C24PKV CS C28PKV ...
Page 15: ...15 5 2 Outdoor Unit 5 2 1 CU C9PKV 5 2 2 CU C12PKV ...
Page 16: ...16 5 2 3 CU C18PKV 5 2 4 CU C24PKV CU C28PKV ...
Page 18: ...18 7 Block Diagram 7 1 1 CS C9PKV CU C9PKV CS C12PKV CU C12PKV ...
Page 19: ...19 7 1 2 CS C18PKV CU C18PKV CS C24PKV CU C24PKV ...
Page 20: ...20 7 1 3 CS C28PKV CU C28PKV ...
Page 25: ...25 9 Electronic Circuit Diagram 9 1 CS C9PKV CU C9PKV CS C12PKV CU C12PKV ...
Page 26: ...26 9 2 CS C18PKV CU C18PKV ...
Page 27: ...27 9 3 CS C24PKV CU C24PKV ...
Page 28: ...28 9 4 CS C28PKV CU C28PKV ...
Page 31: ...31 10 1 4 Comparator Printed Circuit Board 10 1 5 Human Activity Sensor Printed Circuit Board ...
Page 45: ...45 12 2 5 Wire Stripping And Connecting Requirement ...
Page 81: ...81 Figure 3 Figure 4 17 1 1 3 To remove discharge grille Figure 5 ...
Page 83: ...83 Figure 9 Figure 10 ...
Page 87: ...87 Figure 20 Figure 21 ...
Page 88: ...88 18 Technical Data 18 1 Thermostat Characteristics Cooling Soft Dry ...
Page 114: ...114 Printed in Malaysia SZ0313 0 ...