62
13.13 nanoe-G
Operation
•
This operation provides clean air by producing great amount of negative ions and distribute through the
discharge airflow to capture or deactivate molds, bacteria or viruses.
•
nanoe-G operation start condition
o
During unit running at any operation mode, if nanoe-G operation is activated, combination operation
(operation mode + nanoe-G operation) starts.
o
During unit is OFF, if nanoe-G operation is activated, nanoe-G individual operation starts.
•
nanoe-G operation stop condition
o
When OFF/ON button is pressed to stop the operation.
o
When nanoe-G button is pressed.
o
When OFF Timer activates.
•
nanoe-G operation pause condition
o
When indoor fan stop (during deice, odor cut control, thermostat off, etc.). nanoe-G operation resume after
indoor fan restarts.
o
When indoor intake temperature
≥
40°C. nanoe-G operation resume after indoor intake temperature
≤
40°C
continuously for 30 minutes.
•
Indoor
fan
control
o
During any operation mode combines with nanoe-G operation, fan speed follows respective operation mode.
However, nanoe-G system enabled when fan speed
≥
500rpm to ensure proper negative ion distribution,
nanoe-G system disabled when fan speed < 500 rpm.
o
During nanoe-G individual operation, only Auto Fan Speed and no Powerful operation is allowed. Even if Fan
Speed button is pressed, no signal is sent to the unit and no change on remote control display. Auto Fan
Speed for nanoe-G operation changes from SHi to Hi after 4 hours of operation.
•
Airflow direction control
o
During any operation mode combines with nanoe-G operation, airflow direction follows respective operation
mode.
o
During nanoe-G individual operation, only Auto Air Swing is allowed. Even if Air Swing button is pressed, no
signal is sent to the unit and no change on remote control display.
•
Timer
control
o
When ON Timer activates when unit stops, previous operation resumes and restored last saved nanoe-G
operation status.
o
When ON Timer activates during any operation, no change on current operation.
o
When OFF Timer activates during any operation, all operation stops and the latest nanoe-G operation status
is saved.
•
Indicator
o
When nanoe-G starts, nanoe-G indicator ON.
•
Remote Control Receiving Sound
o
Normal
Operation
Î
nanoe-G Operation
: Beep
o
Nanoe-G
Operation
Î
Normal Operation
: Beep
o
Stop
Î
nanoe-G individual Operation : Beep
o
Nanoe-G individual Operation
Î
Stop
: Long Beep
•
Power
failure
o
During nanoe-G individual operation, if power failure occurs, after power resumes, nanoe-G individual
operation resumes immediately.
o
During combination operation, if power failure occurs, after power resumes, combination operation resume
immediately.
Summary of Contents for CS-C12PKV
Page 12: ...12 4 Location of Controls and Components 4 1 Indoor Unit 4 2 Outdoor Unit 4 3 Remote Control ...
Page 13: ...13 5 Dimensions 5 1 Indoor Unit 5 1 1 CS C9PKV CS C12PKV ...
Page 14: ...14 5 1 2 CS C18PKV CS C24PKV CS C28PKV ...
Page 15: ...15 5 2 Outdoor Unit 5 2 1 CU C9PKV 5 2 2 CU C12PKV ...
Page 16: ...16 5 2 3 CU C18PKV 5 2 4 CU C24PKV CU C28PKV ...
Page 18: ...18 7 Block Diagram 7 1 1 CS C9PKV CU C9PKV CS C12PKV CU C12PKV ...
Page 19: ...19 7 1 2 CS C18PKV CU C18PKV CS C24PKV CU C24PKV ...
Page 20: ...20 7 1 3 CS C28PKV CU C28PKV ...
Page 25: ...25 9 Electronic Circuit Diagram 9 1 CS C9PKV CU C9PKV CS C12PKV CU C12PKV ...
Page 26: ...26 9 2 CS C18PKV CU C18PKV ...
Page 27: ...27 9 3 CS C24PKV CU C24PKV ...
Page 28: ...28 9 4 CS C28PKV CU C28PKV ...
Page 31: ...31 10 1 4 Comparator Printed Circuit Board 10 1 5 Human Activity Sensor Printed Circuit Board ...
Page 45: ...45 12 2 5 Wire Stripping And Connecting Requirement ...
Page 81: ...81 Figure 3 Figure 4 17 1 1 3 To remove discharge grille Figure 5 ...
Page 83: ...83 Figure 9 Figure 10 ...
Page 87: ...87 Figure 20 Figure 21 ...
Page 88: ...88 18 Technical Data 18 1 Thermostat Characteristics Cooling Soft Dry ...
Page 114: ...114 Printed in Malaysia SZ0313 0 ...