-19-
●
Resetting the Operating Range Lower Limit
• Keep the MEMORY Switch on the control panel
depressed, then simultaneously press PRESET-7
Switch and PRESET-8 Switch for 5 seconds or more.
• When the LED of PRESET-10 Switch lights, it indicates
that the limit has been reset. Release the switches.
●
Resetting the Operating Range Left Limit
• Keep the MEMORY Switch on the control panel
depressed, then simultaneously press PRESET-1
Switch and PRESET-6 Switch for 5 seconds or more.
• When the LED of PRESET-10 Switch lights, it indicates
that the limit has been reset. Release the switches.
●
Resetting the Operating Range Right Limit
• Keep the MEMORY Switch on the control panel
depressed, then simultaneously press PRESET-4
Switch and PRESET-9 Switch for 5 seconds or more.
• When the LED of PRESET-10 Switch lights, it indicates
that the limit has been reset. Release the switches.
■
Setting the Limiters Again
The same operation alternately applies to setting the
limiters and resetting the limiters.
To set the limiters again, reset the limiters and repeat
the steps for setting the limiters.
The existing limiter settings can be set again by taking
the following steps.
• Reset the desired limits by following the procedures
described in Resetting the Limiters.
• Set the desired limits again by following the procedures
described in Setting the Limiters.