-18-
Switch and PRESET-6 Switch for 5 seconds or more.
• When the LED for PRESET-5 Switch lights to indicate
that the left limit has been set, release the switches.
• Check on the control panel that the left limit has been
correctly set.
●
Setting the Operating Range Right Limit
• Turn the camera to the desired right limit from the con-
trol panel.
• Keep the MEMORY Switch on the control panel
depressed, then simultaneously press PRESET-4
Switch and PRESET-9 Switch for 5 seconds or more.
• When the LED for PRESET-5 Switch lights to indicate
that the right limit has been set, release the switches.
• Check on the control panel that the right limit has been
correctly set.
■
Resetting the Limiters
The set limiters can be released by taking the following
steps.
●
Resetting the Operating Range Upper Limit
• Keep the MEMORY Switch on the control panel
depressed, then simultaneously press PRESET-2
Switch and PRESET-3 Switch for 5 seconds or more.
• When the LED of PRESET-10 Switch lights, it indicates
that the limit has been reset. Release the switches.
■
Setting the Limiters
●
Setting the Operating Range Upper Limit
• Turn the camera to the desired upper limit from the
control panel.
• Keep the MEMORY Switch on the control panel
depressed, then simultaneously press PRESET-2
Switch and PRESET-3 Switch for 5 seconds or more.
• When the LED for PRESET-5 Switch lights to indicate
that the upper limit has been set, release the switches.
• Check on the control panel that the upper limit has
been correctly set.
●
Setting the Operating Range Lower Limit
• Turn the camera to the desired lower limit from the
control panel.
• Keep the MEMORY Switch on the control panel
depressed, then simultaneously press PRESET-7
Switch and PRESET-8 Switch for 5 seconds or more.
• When the LED for PRESET-5 Switch lights to indicate
that the lower limit has been set, release the switches.
• Check on the control panel that the lower limit has
been correctly set.
●
Setting the Operating Range Left Limit
• Turn the camera to the desired left limit from the con-
trol panel.
• Keep the MEMORY Switch on the control panel
depressed, then simultaneously press PRESET-1