• It may be necessary to upgrade the version of the controller in order to support the unit.
For details on upgrading, visit the support page on the following website.
http://pro-av.panasonic.net/
<NOTE>
• The following operations can not be performed via the following controllers.
Item
AW-RP555
AW-RP655
Camera OSD menu operation
Supported
Supported
Scene
Supported
*
1
(1/2/3/USER)
Supported
(HALOGEN/FLUORESCENT/OUTDOOR/USER)
Iris Mode
Supported
Supported
Shutter Mode
Supported with some restrictions
*
2
(Step only)
Not supported
Gain
Supported
*
1
Supported with some restrictions
*
3
ND Filter
Not supported
Not supported
Day/Night
Supported with some restrictions
*
4
Supported with some restrictions
*
4
White Balance Mode
Supported
*
1
(AWB A/AWB B/ATW only)
Supported
(AWB A/AWB B/ATW only)
AWB/ABB
Supported
Supported
Color Temperature
Not supported
Not supported
R Gain / B Gain
Not supported
Supported
Pedestal
Not supported
Supported
R Pedestal / B Pedestal
Not supported
Supported with some restrictions
*
5
Detail
Not supported
Not supported
V Detail Level
Not supported
Not supported
CAM/BAR
Supported
*
1
Supported
Pan
Supported
Supported
Tilt
Supported
Supported
Preset
Supported
Supported
Preset Speed
Not supported
Not supported
Preset Speed Table
Not supported
Not supported
Preset Scope
Not supported
Not supported
Freeze During Preset
Not supported
Not supported
Focus Mode
Supported with some restrictions
*
4
Supported with some restrictions
*
4
Zoom
Supported
Supported
Digital Extender
Not supported
Not supported
OIS/D.I.S.S.
Not supported
Not supported
Tally
Supported with some restrictions
*
6
Supported with some restrictions
*
6
*
1
If the setting value is changed on another device, it may take some time for the setting value to be applied.
*
2
If the Shutter Mode is not turned off/on after configuration, the value will not be changed.
*
3
Improper operation will occur when Gain is set to 19 dB or higher.
*
4
If the setting value is changed on another device, the setting value will not be applied. (If the value is configured locally on the device, the value will
be applied.)
*
5
The value range display will be incorrect (–150 to +150).
*
6
Although the unit is not equipped with a tally lamp, the “OSD Off With Tally” function can be used.
z
Functions that cannot be controlled with the standard protocol
Operations for the following items cannot be controlled with the standard protocol.
Item
Standard protocol incompatibility
Heater
Control not possible
Wiper
Control not possible
Defroster
Control not possible
Washer
Control not possible
OIS/D.I.S.S.
Setting not possible
Audio
Setting not possible
DC Out
Control not possible
Tally
Display function not available on unit
Controller supported