SNMP version
Sets the SNMP version to be enabled.
Setting value:
SNMPv1/v2
Operation will occur using SNMPv1 or SNMPv2.
Either version will be used, or the operation mode of
the SNMP manager will decide.
SNMPv3
Operation will occur using SNMPv3. The operation
mode of the SNMP manager will not operate on a
setting other than SNMPv3.
SNMPv1/v2/v3
Operation will occur using SNMPv1, SNMPv2
or SNMPv3. Either version will be used, or the
operation mode of the SNMP manager will decide.
Factory settings:
SNMPv1/v2
<NOTE>
• When using SNMPv1 or SNMPv2, be sure to input the [Community]
field. The SNMP function cannot be used if the [Community] field is
left blank.
• When using SNMPv3, be sure to input the [User name] and
[Password] fields, and select the desired [Authentication] and
[Encryption method]. The SNMP function cannot be used if any of
these fields are left blank.
• The transmissions are encrypted only during SNMPv3 operation.
SNMPv1/v2 - Community
Input the name of the community to be monitored.
Maximum number
of characters
0 to 32 characters
Invalid characters
Full size characters
Factory settings:
blank
SNMPv3 - User name
Input the user name for user authentication.
The user name that you input here will need to be specified in the
SNMPv3 manager.
Maximum number
of characters
0 to 32 characters
Invalid characters
Full-size characters
Factory settings:
blank
SNMPv3 - Authentication
Sets the algorithm to be used for user authentication.
Setting value:
MD5
The MD5 algorithm will be used for user authentication.
SHA1
The SHA1 algorithm will be used for user authentication.
Factory settings:
MD5
SNMPv3 - Encryption method
Sets the encryption method to be used for transmissions.
Setting value:
DES
DES encryption method for SNMPv3 will be used for
transmissions.
AES
AES encryption method for SNMPv3 will be used for
transmissions.
Factory settings:
DES
SNMPv3 - Password
Sets the password to be used for user authentication.
The password that you input here will need to be specified in the
SNMPv3 manager.
Maximum number
of characters
When [Authentication] is set to [MD5]:
8 to 16 characters
When [Authentication] is set to [SHA1]:
8 to 20 characters
Invalid characters
Full-size characters
Factory settings:
blank
System name
Input the name of the system to control the unit with the SNMP
function.
Maximum number
of characters
0 to 32 characters
Invalid characters
Full size characters
Factory settings:
blank
Location
Input the location where the unit has been installed.
Maximum number
of characters
0 to 32 characters
Factory settings:
blank
Contact
Input the email address or telephone number of the administrator.
Maximum number
of characters
0 to 255 characters
Invalid characters
Full size characters
Factory settings:
blank
z
z
RTSP
This performs settings related to the RTSP function. The RTSP
function sets the RTSP transmission port and RTSP Request URL
used during IP image transmission.
RTSP port
Sets the RTSP reception port no.
Port Nos. that can be selected:
1 to 65535
The following port numbers are used by the unit so they cannot be
used.
20, 21, 23, 25, 42, 53, 67, 68, 69, 80, 110, 123, 161, 162, 443, 995,
10669, 10670, 59000 to 61000
Factory settings:
554
RTSP Request URL (1) to (4)
Sets up the URL for RTSP when making IP image transmission
demands to this unit.
RTSP Request URL (1)
RTSP URL for H.264 (1) image transmission
RTSP Request URL (2)
RTSP URL for H.264 (2) image transmission
RTSP Request URL (3)
RTSP URL for H.264 (3) image transmission
RTSP Request URL (4)
RTSP URL for H.264 (4) image transmission
Factory settings:
RTSP Request URL (1)
MediaInput/h264/stream_1
RTSP Request URL (2)
MediaInput/h264/stream_2
RTSP Request URL (3)
MediaInput/h264/stream_3
RTSP Request URL (4)
MediaInput/h264/stream_4
• Up to 255 characters can be entered.
• The following characters can be displayed.
Half-size numeric characters
0123456789
Half-size English characters
(upper and lower cases)
ABCDEFGHIJKLMNOPQRSTUVWXYZ
abcdefghijklmnopqrstuvwxyz
Half-size symbols
/ - _
<NOTE>
• RTSP Request URL (1) to (4) cannot have the same URL.
92