Aquarea air/water heat pump – Installation manual for monobloc and split systems C, D and E series 05 / 2014
4
Location /
Installation
Location | Installing and fastening the devices
Location
Monobloc systems or split system outdoor units
Minimum clearances of the monobloc unit or split system outdoor unit to adjacent walls
and objects, indicating the air flow direction .
1
Minimum clearance
100 mm
2
Minimum clearance:
Monobloc systems
300 mm
Split systems
100 mm
3
Minimum clearance 1,000 mm
2
1
2
3
Minimum clearances
• The minimum clearances (see Figure) must be observed .
Air circulation
• In general, choose an installation location with good air circulation
• No additional guards such as awnings etc .
• No sources of heat or steam nearby
• No objects nearby which could short circuit the exhaust air
• No direct wind impact on the suction side of the unit
• If multiple units are used, observe the minimum clearance between
units
1
Minimum clearance 100 mm
1
Correct alignment of multiple monobloc units or split system outdoor units
Incorrect Incorrect Correct