External control
25
Output Specification
・
Rated load voltage: 5 V DC to 28 V DC
・
Max. load current: 100 mA (per 1 output)
When 5 V internal voltage is used, set the total of maximum load current to less
than 250mA.
・
Maximum voltage drop is less than 0.9 V when output is given.
■
Product type switching table
Type No.
Pin No.7
Pin No.6
Pin No.5
Remark
0
OFF
OFF
OFF
Product type switching is enabled when all
pins are off.
1
OFF
OFF
ON
2
OFF
ON
OFF
3
OFF
ON
ON
4
ON
OFF
OFF
5
ON
OFF
ON
6
ON
ON
OFF
7
ON
ON
ON
When an external signal is on, the product
type set by the external signal has priority.
* The green display will show a flashing “.”
(period). Irradiation intensity and irradiation
time settings cannot be performed using the
controller.
■