3-24
1-29. Slide Rod Unit Replacement
& Adjustment
(except Camera Recorder)
(Removal)
1. Remove the L-M Release Angle Unit. (Refer to
item 1-28)
2. Remove the Reel Drive Sensor P.C.Board.
(Refer to item 1-27).
3. Remove the Cut Washer (A) and remove the
Reel Drive Cam Gear as shown in Figure 1-29-1.
4. Remove the Cut Washer (B) and remove the
MIC Drive Arm Unit as shown in Figure 1-29-1.
5. Remove the Cut Washer (C) and remove the
MIC Geneva Gear as shown in Figure 1-29-1.
6. Remove the Cut Washer (D) and remove the
Reel Drive Arm Unit as shown in Figure 1-29-2.
7. Remove the Supply and Take Up Reel Rotor
Unit. (Refer to item 1-5)
8. Remove the 2 Cut Washers (E) and remove the
Supply and Take Up Base Drive Arm Unit.
9. Remove the 2 Cut Washers (F) and remove the
Slide Rod Unit.
(Installation)
1. Install the new Slide Rod Unit follow the removal
steps in reverse order.
2. When install the Reel Drive Cam Gear and MIC
Geneva Gear, then phase adjustment should be
performed as follows.
Figure 1-29-2
Figure 1-29-1
Summary of Contents for AJD440 - DVCPRO PLAYER
Page 17: ...2 1 1 Name of Tape Transportation ...
Page 103: ...3 27 2 3 SERVO P C Board Type C D Model ...