90
Menu Copy
Use this function to copy menu
settings from this recorder to another
memory card recorder (referred to as
“a second recorder” in this manual).
Operations on this recorder
1. Connect a USB memory
device to this recorder.
The configuration file
∗
1
cannot be
output to a P2 card.
2. Select [Service] - [Operations]
- [Menu Copy], and press [ ]
to confirm the entry.
A confirmation dialog box appears.
3. Select “Copy”, and accept by
pressing the [ ] button.
This creates a configuration file
∗
1
in the root directory on the USB
memory device.
Select “Cancel” to stop menu copy.
Operations on a second recorder
Using a USB memory device
1. Connect the USB memory
device to the second recorder.
2. Open the P2 card slot cover.
3. With the P2 card slot cover open,
keep pressing the [REC] button
on the second recorder until the
[READY] or [BUSY] lamp starts to
flash (about 10 seconds or more).
The configuration file
∗
1
is loaded.
Loading takes between 20 to 50
seconds. The [READY]
∗
2
lamp lights
when the file has been successfully
loaded.
4. Press the [STOP] button.
The second recorder reboots and
will now run using the same settings
as this recorder.
∗
1 The configuration file is the file
with the “.CFG” extension. The
configuration file contains all
information set on this recorder
excluding the following data.
• AG-CPD15 Operating Time
• FAN Operating Time
• CAM1 Operating Time
• AG-RCP30 Operating Time
• LCD Lighting Time
• AG-CPD15 Version
• BIOS Creation Date
• Microcontroller Version
• AG-RCP30 Version
• Last errors
∗
2 The following lamp states indicate
that an error has occurred.
[BUSY] lamp fast blinking:
This indicates that an error occurred
during configuration file
∗
1
check or
administrator authentication.
• If a configuration file
∗
1
check error
occurred, the following are probable
causes.
- The configuration file is missing.
- There are multiple configuration
files.
- The configuration file is corrupted.
• If an administrator authentication
error occurred, administrator setup
has been made on the second
recorder. Use a PC to copy the
administrator’s officer data to the
\WIDKEY on the USB memory
device. For details regarding text
files containing administrator's
officer data, see “Text Files Used
with the Recorder” on pages 43
- 46. Then perform “Operations on
a second recorder” starting from
step 1 again.
[READY] lamp goes off:
This indicates that the data could
not be correctly loaded. Perform the
operations below in the stated order.
If the [READY] lamp still does not
light, consult your supplier.
Administrator Setup