119
T
roubleshooting
and Reference
Error messages
(continued)
No.
Message
Measure
E20801 The recorder reboots by
unrecoverable card ejection
error.
Be sure to use the correct procedure to
remove and load P2 cards.
E20802 The recorder reboots by
unrecoverable card insertion
error.
E20803 Card is not ready.
Please try to reinsert the card,
or Reboot from Menu.
Check the P2 card and re-insert it, or
reboot this unit.
E20901 Firmware Update FAILED!
An error occurred during the update.
• Check whether the update file for this
unit has been correctly copied to the
P2 card or USB memory device.
• Reformat the P2 card or USB memory
device before use.
• Use another USB memory device.
• Check whether there are multiple
update files on the P2 card or USB
memory device.
• Check whether there are multiple P2
cards and/or USB memory devices
containing update files.
• A P2 card with a \DATA folder cannot
be used for updating.
• A USB memory device containing a
folder other than the \WIDKEY folder
cannot be used for updating.
E20911 Microcontroller Update
FAILED!
An error occurred during the update.
This unit reboots automatically to restart
an update.
Contact your supplier if the problem
persists.
E20912 Unsupported Microcontroller
Detected!
This unit has broken down.
Contact your supplier.
E20921 AG-RCP30 Update FAILED!
An error occurred during an update of
an AG-RCP30 connected to this unit.
This unit reboots automatically to restart
an update.
Contact your supplier if the problem
persists.