Basic O
p
eration
Remote control operation
E
NGLISH - 25
J
Adjustment example
Project a commercial test signal for picture
adjustment on the screen and press the
WAVEFORM
button.
Q
Adjusting with luminance options
1. Press the
ENTER
button several times to display
FULL SCAN(Y)
/
SINGLE LINE SCAN(Y)
.
In
SINGLE LINE SCAN
mode, select the required
adjusting point by pressing
F
G
.
2. Press the
PICTURE ADJUSTMENT
button and
display the
BRIGHTNESS
by pressing
F
G
.
When
ADVANCED MENU
is displayed, press the
button again to switch to the
PICTURE
menu.
3. Adjust by pressing
I
H
.
Adjust the bottom line of the waveform to 0 % (0 or
7.5 IRE).
Setting range: -32 to +32
4. Press
F
G
to display the
CONTRAST
.
5. Adjust by pressing
I
H
.
Adjust the up line of the waveform to 100 %
(100 IRE).
Setting range: -64 to +64
Q
Adjusting with RGB options
1. Press the
ENTER
button several times to display
the required R/G/B waveform option.
In
SINGLE LINE SCAN
mode, select the required
adjusting point by pressing
F
G
.
2. Press the
PICTURE ADJUSTMENT
button and
display the
BRIGHTNESS R
/
BRIGHTNESS G
/
BRIGHTNESS B
by pressing
F
G
.
When
PICTURE
menu is displayed, press the button
again to switch to the
ADVANCED MENU
.
3. Adjust by pressing
I
H
.
Adjust the bottom line of the waveform to 0 % (0 or
7.5 IRE).
Setting range: -16 to +16
4. Press
F
G
to display the
CONTRAST R
/
CONTRAST G
/
CONTRAST B
.
5. Adjust by pressing
I
H
.
Adjust the up line of the waveform to 100 %
(100 IRE).
Setting range: -32 to +32
100%
50%
0%
100%
50%
0%
100%
50%
0%
ENTER
ENTER
Image
displayable area
Adjust to 100%
Adjust to 0%
Monitor position
Image
displayable area
Adjust to 100%
Adjust to 0%
Monitor position
Signal level
Sign
al level
With
COMPUTER
(except 1080) or
HDMI
(Expand)
FULL SCAN(Y)/SINGLE LINE SCAN(Y)
BRIGHTNESS
Adjust the bottom line of the
waveform to 0 % (0 or 7.5 IRE)
CONTRAST
Adjust the top line of the waveform to
100 % (100 IRE)
FULL SCAN(R)/SINGLE LINE SCAN(R)
BRIGHTNESS R
Adjust the bottom line of the
waveform to 0 % (0 or 7.5 IRE)
CONTRAST R
Adjust the top line of the waveform to
100 % (100 IRE)
FULL SCAN(G)/SINGLE LINE SCAN(G)
BRIGHTNESS G
Adjust the bottom line of the
waveform to 0 % (0 or 7.5 IRE)
CONTRAST G
Adjust the top line of the waveform to
100 % (100 IRE)
FULL SCAN(B)/SINGLE LINE SCAN(B)
BRIGHTNESS B
Adjust the bottom line of the
waveform to 0 % (0 or 7.5 IRE)
CONTRAST B
Adjust the top line of the waveform to
100 % (100 IRE)
Summary of Contents for AE3000U - LCD Projector - HD 1080p
Page 60: ...Printed in Japan S0908 2108C ...