background image

7

FEATURE DETAILS

Filtered Outlet Banks  

Eight Outlets (4 banks / 2 outlets per bank) are fed through cascaded noise filtration circuits. These circuits are designed to
eliminate AC contamination that is detrimental to the performance of audio or video components like stereo receivers, VCRs
or televisions. The dedicated filters are carefully engineered to provide power filtration and inter-component "noise isolation"
for both “common-mode” (line/neutral to ground) and "normal-mode" (line-to-neutral) EMI/RFI. This means that high-fre-
quency interference will be drastically reduced not only from the incoming power but also from equipment plugged into the
other outlet banks, regardless of what "mode" it occurs in. Even equipment with ungrounded, 2-blade plugs, receives clean
power. 

As shown in the diagram, there are four banks of filtered outlets (not counting the High Current outlets and the front panel
convenience outlet). Cascaded filter circuits are used to feed the various banks and provide maximum noise isolation and
attenuation.  All 4 banks benefit from the inductorless input filter, the Common Mode Balanced L filter and  Normal Mode
Balanced L filter circuits.  Outlet banks 2 and 4 receive their clean power through this comprehensive network of filters while
banks 1 and 3 benefit from additional Balanced L filters.

Outlet Banks 1 and 2

contains four switched outlets that will turn your connected equipment ON or OFF with one of two

MAX

® 

5410 triggers front panel push-button or Voltage Sense Trigger. A 2-position slide switch located on the rear panel

controls the timing.  Together, these outlets can be set as Always-On or with a turn-off delay of 10 seconds to prevent speak-
er "thump". This switch provides the option of having a total of eight always-on outlets. See the Sequential Startup/Shutdown
section for more information.

Outlet Bank 3 and 4

remain ON continually to provide a constant power source for programmable audio/video compo-

nents. A personal video recorder (such as TiVo™) and VCR are two examples of components that require a constant supply
of power. A TiVo™ video recorder relies on continual power to monitor the cable signal and retain its programmed informa-
tion. A VCR should be connected to one of these always-on, filtered outlets to maintain correct clock time and programmed
recording information.

When set to 10 second delay position, these outlets will remain as Switched outlets, controlled by the front panel push-but-
ton and/or the DC Voltage Sense Trigger. In this situation, these outlets will not power down until after the selected time has
elapsed.

USA & Canada (800) 472-5555  •  (707) 283-5900  •  Fax (707) 283-5901

ER

T

HIGH CURRENT OUTLETS

SWITCHED OUTLETS

ALWAYS ON OUTLETS

RS232 CO

12V TR
IN         

ER

T

HIGH CURRENT OUTLETS

SWITCHED OUTLETS

ALWAYS ON OUTLETS

RS232 C

12V TR
IN         

     HIGH 
 CURRENT 
 OUTLETS

COMMON MODE
DOUBLE "L" FILTER

BANK 1

BANK 2

BANK 3

BANK 4

FILTERED OUTLET BANKS

SWITCHED 
 OUTLETS

ALWAYS ON 
  OUTLETS

INDUCTORLESS
INPUT FILTER

POWER PROTECTION
       CIRCUITRY

NORMAL
MODE
BALANCED 
"L" FILTER

NORMAL
MODE
BALANCED 
"L" FILTER

NORMAL
MODE
BALANCED 
"L" FILTER

NORMAL
MODE
BALANCED 
"L" FILTER

FRONT
PANEL
CONVENIENCE
OUTLET

WALL
OUTLET

1

2

ER

T

HIGH CURRENT OUTLETS

SWITCHED OUTLETS

ALWAYS ON OUTLETS

RS232 C

12V TR
IN         

3

4

Summary of Contents for MAX 5410

Page 1: ...MAX 5410 Pro Series Owner s Manual AC VOLTS 0 150 METER LIGHT TRIGGER SWITCHED OUTLETS GROUND OK LINE FAULT UNSAFE VOLTAGE 1690 Corporate Circle Petaluma CA 94954 www panamax com...

Page 2: ...in ment gear The combination of sophis ticated noise filtration circuitry and the world s finest surge protection has resulted in an Audio Video power cen ter that meets the power quality needs for ea...

Page 3: ...Coaxial Line Protection 9 Telephone Line Protection 9 AC Power Cord 9 AC Surge Protection 10 SurgeGate Plus Protection 10 Technical Specifications 11 Contacting Panamax 11 Frequently Asked Questions 1...

Page 4: ...minated with this design Outlet Banks 1 and 2 are always on providing continuous power to those components with programmable memory settings Banks 3 and 4 can be set to either always on or switched A...

Page 5: ...OMATION CONTROL DVD PHONE JACK OUTDOOR FM ANTENNA DUAL LNB SATELLITE DISH 12V TRIGGER IN OUT RS 232 USB LED LIGHT HIGH CURRENT OUTLETS SWITCHED OUTLETS ALWAYS ON OUTLETS SATELLITE CATV ANT CIRCUIT BRE...

Page 6: ...ent Outlets Choose between 0 and 10 seconds Outlet Banks 1 and 2 Turn Off Switch 2 position slide switch Allows adjustment of the Turn Off delay for Outlet Bank 1 Choose between 0 and 10 seconds Satel...

Page 7: ...that locks up Diagnostic Lights The MAX 5410 is loaded with special features to save your connected equipment from many different forms of dangerous power disturbances Six diagnostic lights on the fr...

Page 8: ...ncoming voltage from the wall receptacle and provides a visual representation of the available power The voltmeter is ALWAYS ON and indicates the incoming line voltage even during an unsafe voltage co...

Page 9: ...lide switch located on the rear panel controls the timing Together these outlets can be set as Always On or with a turn off delay of 10 seconds to prevent speak er thump This switch provides the optio...

Page 10: ...f the MAX 5410 s switched and high current outlets An AC adapter of the appropriate voltage plugged into a switched outlet on the receiver may also be used if a 12V trigger is not built in The MAX 541...

Page 11: ...ss than 1dB of signal loss throughout the entire 950Mhz to 2 2Ghz range SignalPerfect Telephone Line Protection Satellite TV receivers require a telephone line connection for Pay Per View services The...

Page 12: ...to a safe level 1 Disconnects power to all connected equipment 2 Unsafe Voltage LED is activated and will blink once per second during the unsafe voltage condition The MAX 5410 requires line voltage...

Page 13: ...0V Protection Modes L N L G N G Initial Clamping Level 200V Peak 141V Rms Response Time 1ns Joule Rating 2325 Joules Peak Impulse Current 91 000A Catastrophic Surge Circuit YES AC Line Voltage 120VAC...

Page 14: ...to be repaired or replaced Please refer to the preceding section on Contacting Panamax or the warranty documentation for more information What is the difference between a Surge and Spike A spike is a...

Page 15: ...a MAINACON if all outlets main relay are ON b MAINACOFF if all outlets are OFF c SWITCHEDON if the switched outlets are ON d SWITCHEDOFF if the switched outlets are OFF e HICURRENTON if the high curre...