8

FEATURE DETAILS

Circuit Breaker

A circuit breaker is located on the back panel of the MAX

®

5410.  The circuit breaker will trip only if the total current draw

exceeds the maximum current rating (15A).  This means that collectively, all outlets must draw more than 15 Amps before
the circuit breaker will trip. 

1690 Corporate Circle, Petaluma, CA 94954 •  www.panamax.com

15A BREAKER

GROUND

IEC320 INLET

HIGH CURRENT OUTLETS

SWITCHED OUTLETS

Engineered
in the USA
Assembled

in China

RS232 CONTROL

USB
LED

LIGHT

12V TRIGGER
IN            OUT

TRIGGER 

ENABLE

TRIGGER 

DELAY

HC

OUTLETS

DELAY

SWITCHED

OUTLETS

DELAY

LINE                EQUIP. 1            EQUIP. 2 

SATELLITE

            CATV/ANT

Engineered
in the USA
Assembled

in China

RS232 CONTROL

USB
LED

LIGHT

12V TRIGGER
IN            OUT

TRIGGER 

ENABLE

TRIGGER 

DELAY

HC

OUTLETS

DELAY

SWITCHED

OUTLETS

DELAY

LINE                EQUIP. 1            EQUIP. 2 

SATELLITE

            CATV/ANT

15A BREAKER

GROUND

IEC320 INLET

HIGH CURRENT OUTLETS

SWITCHED OUTLETS

High-Current Outlet Bank

The two high-current outlets allow amplifiers and powered subwoofers to work to their full potential.  When the movie thun-
ders with a terrific explosion or when the music reaches a climactic crescendo, an amplifier has to rapidly draw large amounts
of current to replenish its power supply capacitors.  Traditional line conditioners impede this current draw, in effect, starving
an amplifier and resulting in a flat, dead sound.  The High-Current Outlet Bank provides clean, filtered power to amplifiers
but has no current limiting components to impede performance.

The high-current outlets are designed with a turn-on delay option of 0 or 10 seconds.  The 2-position, Delayed Outlet Turn-
On Switch on the back of the MAX

®

5410 is used to select the desired time delay.  When a delay is selected, the high-cur-

rent outlets will turn-on after Outlet Banks 1 and 2 and turn-off before Outlet Banks 1 and 2 (if they’re not set to Always-On).
With a delay, the connected equipment will not power up simultaneously, thus preventing loudspeaker noises such as
“thumping”.   See the 

Sequential Startup/Shutdown

section for more information.

Voltage Sense Trigger - DC Triggers

Input Trigger -

This feature provides an ON/OFF trigger for the MAX

®

5410 using a DC remote control signal.  Many com-

ponents such as pre-amplifiers and receivers have a 12VDC trigger built-in, and will transmit a constant power signal when
turned on and in use.  This power signal will initiate the startup or shutdown sequence of the MAX

®

5410’s switched and

high current outlets.  An AC adapter of the appropriate voltage, plugged into a switched outlet on the receiver, may also be
used if a 12V trigger is not built in. The MAX

®

5410 voltage sense trigger input uses a standard 3.5mm mini-plug jack. 

Please note:

 The front panel pushbutton must be left in the “ON” position if you are using the DC Input Trigger and not

connected to a Home Automation system through the RS232 port.

Input Trigger Enable Switch –

This switch is used to disable or enable the Input Trigger feature. The circuitry for the volt-

age sense trigger also controls the Voltage Trigger Diagnostic LED on the front panel.  When disabled, the front panel Trigger
LED remains lit and the front panel pushbutton controls the ON/OFF state of the switched and high current outlets.  

When enabled, and a DC voltage is sensed by the Input Trigger circuitry, the front panel Trigger LED will light to indicate that
the voltage sense circuit is ON and the MAX

®

5410’s switched outlets are ON.

Output Trigger –

The MAX

®

5410 is capable of generating its own 12VDC remote signal to control other components.  In

its default state, this output turns ON when the Input Trigger receives a signal and OFF when the input trigger signal is turned
off.  This output also uses a standard 3.5mm mini-plug jack.  

Output Trigger Delay Switch –

This switch allows the selection of 0 or 10 second delay in turning on the 12VDC output

signal.  There is no delay when it turns off.

RS232 Trigger Control – 

The MAX

®

5410’s command set default is “ATTACHTRIG” - refer to page 13 - (Trigger Attached),

meaning that the ON/OFF state of the Output Trigger is dependent on the Input Trigger.  When connected to a Home
Automation system through the RS232 port, operation of the Output Trigger can be divorced from the Input Trigger and the
automation system can control the ON/OFF state of the Output Trigger.  This is accomplished through the “DETACHTRIG”
(Trigger Detached) command.

Engineered
in the USA
Assembled

in China

RS232 CONTROL

USB
LED

LIGHT

12V TRIGGER
IN            OUT

TRIGGER 

ENABLE

TRIGGER 

DELAY

HC

OUTLETS

DELAY

SWITCHED

OUTLETS

DELAY

LINE                EQUIP. 1            EQUIP. 2 

SATELLITE

            CATV/ANT

Engineered
in the USA
Assembled

in China

RS232 CONTROL

USB
LED

LIGHT

12V TRIGGER
IN            OUT

TRIGGER 

ENABLE

TRIGGER 

DELAY

HC

OUTLETS

DELAY

SWITCHED

OUTLETS

DELAY

LINE                EQUIP. 1            EQUIP. 2 

Engineered
in the USA
Assembled

in China

RS232 CONTROL

USB
LED

LIGHT

12V TRIGGER
IN            OUT

TRIGGER 

ENABLE

TRIGGER 

DELAY

HC

OUTLETS

DELAY

SWITCHED

OUTLETS

DELAY

LINE                EQUIP. 1            EQUIP. 2 

Engineered
in the USA
Assembled

in China

RS232 CONTROL

USB
LED

LIGHT

SATELLITE

            CATV/ANT

Summary of Contents for MAX 5410

Page 1: ...MAX 5410 Pro Series Owner s Manual AC VOLTS 0 150 METER LIGHT TRIGGER SWITCHED OUTLETS GROUND OK LINE FAULT UNSAFE VOLTAGE 1690 Corporate Circle Petaluma CA 94954 www panamax com...

Page 2: ...in ment gear The combination of sophis ticated noise filtration circuitry and the world s finest surge protection has resulted in an Audio Video power cen ter that meets the power quality needs for ea...

Page 3: ...Coaxial Line Protection 9 Telephone Line Protection 9 AC Power Cord 9 AC Surge Protection 10 SurgeGate Plus Protection 10 Technical Specifications 11 Contacting Panamax 11 Frequently Asked Questions 1...

Page 4: ...minated with this design Outlet Banks 1 and 2 are always on providing continuous power to those components with programmable memory settings Banks 3 and 4 can be set to either always on or switched A...

Page 5: ...OMATION CONTROL DVD PHONE JACK OUTDOOR FM ANTENNA DUAL LNB SATELLITE DISH 12V TRIGGER IN OUT RS 232 USB LED LIGHT HIGH CURRENT OUTLETS SWITCHED OUTLETS ALWAYS ON OUTLETS SATELLITE CATV ANT CIRCUIT BRE...

Page 6: ...ent Outlets Choose between 0 and 10 seconds Outlet Banks 1 and 2 Turn Off Switch 2 position slide switch Allows adjustment of the Turn Off delay for Outlet Bank 1 Choose between 0 and 10 seconds Satel...

Page 7: ...that locks up Diagnostic Lights The MAX 5410 is loaded with special features to save your connected equipment from many different forms of dangerous power disturbances Six diagnostic lights on the fr...

Page 8: ...ncoming voltage from the wall receptacle and provides a visual representation of the available power The voltmeter is ALWAYS ON and indicates the incoming line voltage even during an unsafe voltage co...

Page 9: ...lide switch located on the rear panel controls the timing Together these outlets can be set as Always On or with a turn off delay of 10 seconds to prevent speak er thump This switch provides the optio...

Page 10: ...f the MAX 5410 s switched and high current outlets An AC adapter of the appropriate voltage plugged into a switched outlet on the receiver may also be used if a 12V trigger is not built in The MAX 541...

Page 11: ...ss than 1dB of signal loss throughout the entire 950Mhz to 2 2Ghz range SignalPerfect Telephone Line Protection Satellite TV receivers require a telephone line connection for Pay Per View services The...

Page 12: ...to a safe level 1 Disconnects power to all connected equipment 2 Unsafe Voltage LED is activated and will blink once per second during the unsafe voltage condition The MAX 5410 requires line voltage...

Page 13: ...0V Protection Modes L N L G N G Initial Clamping Level 200V Peak 141V Rms Response Time 1ns Joule Rating 2325 Joules Peak Impulse Current 91 000A Catastrophic Surge Circuit YES AC Line Voltage 120VAC...

Page 14: ...to be repaired or replaced Please refer to the preceding section on Contacting Panamax or the warranty documentation for more information What is the difference between a Surge and Spike A spike is a...

Page 15: ...a MAINACON if all outlets main relay are ON b MAINACOFF if all outlets are OFF c SWITCHEDON if the switched outlets are ON d SWITCHEDOFF if the switched outlets are OFF e HICURRENTON if the high curre...