FEATURE DETAILS

Protect or Disconnect™ AC Surge Protection

When the MAX

®

5410 is subjected to a high voltage surge, its voltage output is limited to a safe level and the high levels

of surge current are diverted away from the connected equipment.

• When subjected to a 6,000V (open circuit voltage) / 500A (short circuit current) surge, the MAX

®

5410 limits

its voltage output to less than 330V peak, UL’s  lowest rating.  The MAX

®

5410 will withstand, without dam-

age, multiple 12,000A surges, far exceeding the UL maximum requirement of only  3,000 Ampere surges.

• If the magnitude of the surge is greater than the capacity of the surge protection components, the MAX

®

5410’s  Protect or Disconnect™ Circuitry will 

disconnect

your equipment in order to protect it.  The MAX

®

5410 will need to be repaired or replaced by Panamax if this occurs. (See Product Warranty).

SurgeGate Plus™ Protection

The MAX

®

5410 constantly monitors the AC line voltage for unsafe voltage conditions such as prolonged overvoltages and

undervoltages (brownouts).  These unsafe conditions pose a very dangerous threat to all electronic equipment within  the
home.  If the MAX

®

5410 senses an unsafe power condition, it will automatically 

disconnect 

your equipment from the

power to protect equipment from damage.  Once the voltage returns to a safe level, the MAX

®

5410 will automatically

reconnect 

the power.

If the line voltage exceeds the overvoltage threshold (134VAC) or falls below the undervoltage threshold (95VAC), the 
MAX

®

5410 will perform the following tasks until line voltage returns to a safe level:

1. Disconnects power to all connected equipment.
2. Unsafe Voltage LED is activated and will blink once per second during the unsafe voltage condition.

The MAX

®

5410 requires line voltage to return to within the safe operating range for 10 seconds before returning to normal

operating mode.  This is referred to as “Over/Undervoltage Recovery”.  The safe operating range is considered 5V above the
under-voltage threshold (~100V) and 5V below the overvoltage threshold (~129V).  Once this safe operating range is
reached,  the MAX

®

5410 will perform the following functions:

1. 

Unsafe Voltage LED

will blink 4 times per second for Over/Undervoltage Recovery.

2. Power is restored to all connected equipment after the 10-second delay.  The normal start-up sequence 

as determined by the “High-Current Outlets Turn-On Switch” and “Outlet Bank 2 Turn-Off Switch” will 

be followed. 

The MAX

®

5410 provides protection against common problems on the AC power line.  This includes spikes/surges and

sustained overvoltages or undervoltages.  Panamax’s exclusive Protect or Disconnect™ circuitry is designed to protect
against spikes/surges while the SurgeGate Plus™ circuitry is for sustained over/under voltage protection.

1.

Voltage reaches an unsafe high

level and the SurgeGate Plus™ 

disconnects.

2.

Voltage reaches a safe level and

SurgeGate Plus™ automatically 

reconnects.

3.

Voltage reaches an unsafe low level

and SurgeGate Plus™ 

disconnects.

4.

Voltage reaches a safe level and

SurgeGate Plus™ automatically 

reconnects.

1.

Voltage reaches an unsafe level.

2.

If surge is greater than MAX

®

5410

capacity, it 

disconnects.

1690 Corporate Circle, Petaluma, CA 94954 •  www.panamax.com

AC VOLTS

0

150

METER

LIGHT

TRIGGER

SWITCHED

OUTLETS

GROUND

OK

LINE

FAULT

UNSAFE

VOLTAGE

Summary of Contents for MAX 5410

Page 1: ...MAX 5410 Pro Series Owner s Manual AC VOLTS 0 150 METER LIGHT TRIGGER SWITCHED OUTLETS GROUND OK LINE FAULT UNSAFE VOLTAGE 1690 Corporate Circle Petaluma CA 94954 www panamax com...

Page 2: ...in ment gear The combination of sophis ticated noise filtration circuitry and the world s finest surge protection has resulted in an Audio Video power cen ter that meets the power quality needs for ea...

Page 3: ...Coaxial Line Protection 9 Telephone Line Protection 9 AC Power Cord 9 AC Surge Protection 10 SurgeGate Plus Protection 10 Technical Specifications 11 Contacting Panamax 11 Frequently Asked Questions 1...

Page 4: ...minated with this design Outlet Banks 1 and 2 are always on providing continuous power to those components with programmable memory settings Banks 3 and 4 can be set to either always on or switched A...

Page 5: ...OMATION CONTROL DVD PHONE JACK OUTDOOR FM ANTENNA DUAL LNB SATELLITE DISH 12V TRIGGER IN OUT RS 232 USB LED LIGHT HIGH CURRENT OUTLETS SWITCHED OUTLETS ALWAYS ON OUTLETS SATELLITE CATV ANT CIRCUIT BRE...

Page 6: ...ent Outlets Choose between 0 and 10 seconds Outlet Banks 1 and 2 Turn Off Switch 2 position slide switch Allows adjustment of the Turn Off delay for Outlet Bank 1 Choose between 0 and 10 seconds Satel...

Page 7: ...that locks up Diagnostic Lights The MAX 5410 is loaded with special features to save your connected equipment from many different forms of dangerous power disturbances Six diagnostic lights on the fr...

Page 8: ...ncoming voltage from the wall receptacle and provides a visual representation of the available power The voltmeter is ALWAYS ON and indicates the incoming line voltage even during an unsafe voltage co...

Page 9: ...lide switch located on the rear panel controls the timing Together these outlets can be set as Always On or with a turn off delay of 10 seconds to prevent speak er thump This switch provides the optio...

Page 10: ...f the MAX 5410 s switched and high current outlets An AC adapter of the appropriate voltage plugged into a switched outlet on the receiver may also be used if a 12V trigger is not built in The MAX 541...

Page 11: ...ss than 1dB of signal loss throughout the entire 950Mhz to 2 2Ghz range SignalPerfect Telephone Line Protection Satellite TV receivers require a telephone line connection for Pay Per View services The...

Page 12: ...to a safe level 1 Disconnects power to all connected equipment 2 Unsafe Voltage LED is activated and will blink once per second during the unsafe voltage condition The MAX 5410 requires line voltage...

Page 13: ...0V Protection Modes L N L G N G Initial Clamping Level 200V Peak 141V Rms Response Time 1ns Joule Rating 2325 Joules Peak Impulse Current 91 000A Catastrophic Surge Circuit YES AC Line Voltage 120VAC...

Page 14: ...to be repaired or replaced Please refer to the preceding section on Contacting Panamax or the warranty documentation for more information What is the difference between a Surge and Spike A spike is a...

Page 15: ...a MAINACON if all outlets main relay are ON b MAINACOFF if all outlets are OFF c SWITCHEDON if the switched outlets are ON d SWITCHEDOFF if the switched outlets are OFF e HICURRENTON if the high curre...

Reviews: