background image

Engineered

in the USA
Assembled

in China

15A BREAKER

GROUND

IEC320 INLET

HIGH CURRENT OUTLETS

SWITCHED OUTLETS

ALWAYS ON OUTLETS

RS232 CONTROL

USB
LED

LIGHT

12V TRIGGER
IN            OUT

TRIGGER 

ENABLE

TRIGGER 

DELAY

HC

OUTLETS

DELAY

SWITCHED

OUTLETS

DELAY

LINE                EQUIP. 1            EQUIP. 2 

SATELLITE

            CATV/ANT

4

FEATURE OVERVIEW

Front Panel Pushbutton:

1 of 2 Triggers that can activate a 
turn-on or shutdown sequence for 
Outlet Banks 1 and 2 and High-
Current outlets.

See the Featured Details sec-
tion for more information.

LED Indicators:

Status indicator lights for:
• DC Voltage Trigger
• Switched Outlets 
• Ground OK
• Line Fault 
• Unsafe Voltage

LED:

Indicates ON/OFF
status. Flashing
indicates Turn
ON/OFF sequence
in progress.

Meter Light Dimmer:

Controls brightness 
of the Voltmeter 
backlighting.

High-Current Outlet Bank: 

Two delayed outlets designed
for high-current components
such as amplifiers and pow-
ered subwoofers.  The current
available to connected equip-
ment is not limited by the
noise filtration components. 

Voltage Sense 
Trigger Input: 

3.5mm Mini-Plug jack.
Connect to a remote trigger
device that provides 12VDC
to trigger a startup/shutdown
sequence.  This is the sec-
ond trigger that will activate
the MAX

®

5410 turn-on or

shutdown sequence.  (See
pushbutton on front panel).

Voltage Sense 
Trigger Output: 

3.5mm Mini-Plug jack.
Supplies a 12VDC 
trigger to control 
the startup/shutdown 
of an additional device.

High-Current
Outlets Turn-On
Switch: 

2-position slide
switch.  Allows
adjustment of the
Turn-On delay for
the two High-Current
Outlets.  Choose
between 0 and 10 
seconds.

Outlet Banks 
1 and 2 Turn-Off
Switch: 

2-position slide 
switch.  Allows 
adjustment of the 
Turn-Off delay for 
Outlet Bank 1.  
Choose between 
0 and 10 seconds. 

Satellite 
Coax Jacks: 

Two pairs of gold
plated F-Connectors
optimized for 
Satellite TV signal 
line protection.

RS232
Connection:

For home
automation
systems.

USB Style
Port for 
LED 
Light

Cable TV 
Coax Jacks: 

Two pairs of gold
plated F-Connectors
optimized for Cable
TV and non-amplified
Rooftop Antenna 
signal line protection.

Telephone Jacks:

In/Out connections
for telephone line or
pay-per-view line
protection. Integrated
lone splitter allows
two devices to be
connected to one
phone line.

Input
Trigger 
Enable
Switch

Output
Trigger
Delay
Switch

Voltmeter:

Backlit analog meter
measures incoming
voltage source from
0-150 VAC.

Convenience Outlet:

Provides a quick convenient
way to plug in components
such as camcorders and
video game systems.

IEC Main Power
Receptacle: 

Power cord connects
to this receptacle.

15A Circuit Breaker: 

Opens in the event that
equipment plugged into
the MAX

®

5410 draws

too much current.  When
the white button of the
breaker is visible, the
breaker has opened.
Reduce the load and
push to reset.

Ground Lug:

Provides

a common grounding
point for equipment with
separate ground leads.

Filtered Outlet 
Banks 3 and 4: 

Four Always-On outlets for
audio/video components that
require constant power to
maintain programmed settings.

Filtered Outlet 
Banks 1 and 2: 

Four switched outlets for
audio/video components
that do not require con-
stant power.

1690 Corporate Circle, Petaluma, CA 94954 •  www.panamax.com

AC VOLTS

0

150

METER

LIGHT

TRIGGER

SWITCHED

OUTLETS

GROUND

OK

LINE

FAULT

UNSAFE

VOLTAGE

1

2

3

4

Summary of Contents for MAX 5410

Page 1: ...MAX 5410 Pro Series Owner s Manual AC VOLTS 0 150 METER LIGHT TRIGGER SWITCHED OUTLETS GROUND OK LINE FAULT UNSAFE VOLTAGE 1690 Corporate Circle Petaluma CA 94954 www panamax com...

Page 2: ...in ment gear The combination of sophis ticated noise filtration circuitry and the world s finest surge protection has resulted in an Audio Video power cen ter that meets the power quality needs for ea...

Page 3: ...Coaxial Line Protection 9 Telephone Line Protection 9 AC Power Cord 9 AC Surge Protection 10 SurgeGate Plus Protection 10 Technical Specifications 11 Contacting Panamax 11 Frequently Asked Questions 1...

Page 4: ...minated with this design Outlet Banks 1 and 2 are always on providing continuous power to those components with programmable memory settings Banks 3 and 4 can be set to either always on or switched A...

Page 5: ...OMATION CONTROL DVD PHONE JACK OUTDOOR FM ANTENNA DUAL LNB SATELLITE DISH 12V TRIGGER IN OUT RS 232 USB LED LIGHT HIGH CURRENT OUTLETS SWITCHED OUTLETS ALWAYS ON OUTLETS SATELLITE CATV ANT CIRCUIT BRE...

Page 6: ...ent Outlets Choose between 0 and 10 seconds Outlet Banks 1 and 2 Turn Off Switch 2 position slide switch Allows adjustment of the Turn Off delay for Outlet Bank 1 Choose between 0 and 10 seconds Satel...

Page 7: ...that locks up Diagnostic Lights The MAX 5410 is loaded with special features to save your connected equipment from many different forms of dangerous power disturbances Six diagnostic lights on the fr...

Page 8: ...ncoming voltage from the wall receptacle and provides a visual representation of the available power The voltmeter is ALWAYS ON and indicates the incoming line voltage even during an unsafe voltage co...

Page 9: ...lide switch located on the rear panel controls the timing Together these outlets can be set as Always On or with a turn off delay of 10 seconds to prevent speak er thump This switch provides the optio...

Page 10: ...f the MAX 5410 s switched and high current outlets An AC adapter of the appropriate voltage plugged into a switched outlet on the receiver may also be used if a 12V trigger is not built in The MAX 541...

Page 11: ...ss than 1dB of signal loss throughout the entire 950Mhz to 2 2Ghz range SignalPerfect Telephone Line Protection Satellite TV receivers require a telephone line connection for Pay Per View services The...

Page 12: ...to a safe level 1 Disconnects power to all connected equipment 2 Unsafe Voltage LED is activated and will blink once per second during the unsafe voltage condition The MAX 5410 requires line voltage...

Page 13: ...0V Protection Modes L N L G N G Initial Clamping Level 200V Peak 141V Rms Response Time 1ns Joule Rating 2325 Joules Peak Impulse Current 91 000A Catastrophic Surge Circuit YES AC Line Voltage 120VAC...

Page 14: ...to be repaired or replaced Please refer to the preceding section on Contacting Panamax or the warranty documentation for more information What is the difference between a Surge and Spike A spike is a...

Page 15: ...a MAINACON if all outlets main relay are ON b MAINACOFF if all outlets are OFF c SWITCHEDON if the switched outlets are ON d SWITCHEDOFF if the switched outlets are OFF e HICURRENTON if the high curre...

Reviews: