background image

FEATURE DETAILS

6

Ground OK: 

Green LED.  When this light is ON, it indicates that the wall outlet is properly wired.  When the light is OFF,

it indicates that the wall outlet has a reversed line and neutral wire, or that there is no ground present. 

Line Fault: 

Red LED. When this light is ON, it is indicating that the wall outlet has a reversed line and neutral wire, or

there is no ground present.  This light will remain OFF if the wall outlet is properly wired. 

Unsafe Voltage: 

Red LED.  Under normal voltage conditions, this light stays OFF.  When this light is FLASHING slow-

ly (once per second), it indicates an undervoltage (<95 VAC) or overvoltage (>134 VAC) condition.  When the light is flash-
ing quickly (4 times per second), it indicates a 10 second recovery period from an under/overvoltage condition.  This light
will flash quickly when the MAX

®

5410 is first plugged into the wall outlet.

Meter Light Control 

Controls the brightness level, or turns the lighting off altogether.

Voltmeter

The analog Voltmeter is backlit to provide the ability to view the reading in a dark room.  LEDs (light emitting diodes) are
used as the light source in order to provide durability and long life.  The “Meter Light” dimmer controls the brightness level,
or turns the lighting off altogether.

The Voltmeter monitors the incoming voltage from the wall receptacle and provides a visual representation of the available
power.  The voltmeter is ALWAYS-ON and indicates the incoming line voltage even during an unsafe voltage condition.
Readings above 150VAC  will not be accurate due to the meter’s damping characteristics.

Convenience Outlet

A single outlet on the front panel of the MAX

®

5410 provides an easy to reach power source for electronic equipment typi-

cally used on a part time basis.  Such equipment includes anything from video game systems to camcorders. 

The convenience outlet not only provides superior surge suppression, but also taps into Filter Circuits to provide clean power
for your sensitive electronic equipment.  This outlet is an Always-On outlet and will continually supply a steady source of
power for your connected equipment.  

It is important to remember that power will be disconnected only in the event

of an unsafe voltage condition.

1690 Corporate Circle, Petaluma, CA 94954 •  www.panamax.com

AC VOLTS

0

150

METER

LIGHT

TRIGGER

SWITCHED

OUTLETS

GROUND

OK

LINE

FAULT

UNSAFE

VOLTAGE

AC VOLTS

0

150

METER

LIGHT

TRIGGER

SWITCHED

OUTLETS

GROUND

OK

LINE

FAULT

UNSAFE

VOLTAGE

AC VOLTS

0

150

METER

LIGHT

TRIGGER

SWITCHED

OUTLETS

GROUND

OK

LINE

FAULT

UNSAFE

VOLTAGE

AC VOLTS

0

150

METER

LIGHT

TRIGGER

SWITCHED

OUTLETS

GROUND

OK

LINE

FAULT

UNSAFE

VOLTAGE

AC VOLTS

0

150

METER

LIGHT

TRIGGER

SWITCHED

OUTLETS

GROUND

OK

LINE

FAULT

UNSAFE

VOLTAGE

AC VOLTS

150

(Diagnostic Lights Continued)

Summary of Contents for MAX 5410

Page 1: ...MAX 5410 Pro Series Owner s Manual AC VOLTS 0 150 METER LIGHT TRIGGER SWITCHED OUTLETS GROUND OK LINE FAULT UNSAFE VOLTAGE 1690 Corporate Circle Petaluma CA 94954 www panamax com...

Page 2: ...in ment gear The combination of sophis ticated noise filtration circuitry and the world s finest surge protection has resulted in an Audio Video power cen ter that meets the power quality needs for ea...

Page 3: ...Coaxial Line Protection 9 Telephone Line Protection 9 AC Power Cord 9 AC Surge Protection 10 SurgeGate Plus Protection 10 Technical Specifications 11 Contacting Panamax 11 Frequently Asked Questions 1...

Page 4: ...minated with this design Outlet Banks 1 and 2 are always on providing continuous power to those components with programmable memory settings Banks 3 and 4 can be set to either always on or switched A...

Page 5: ...OMATION CONTROL DVD PHONE JACK OUTDOOR FM ANTENNA DUAL LNB SATELLITE DISH 12V TRIGGER IN OUT RS 232 USB LED LIGHT HIGH CURRENT OUTLETS SWITCHED OUTLETS ALWAYS ON OUTLETS SATELLITE CATV ANT CIRCUIT BRE...

Page 6: ...ent Outlets Choose between 0 and 10 seconds Outlet Banks 1 and 2 Turn Off Switch 2 position slide switch Allows adjustment of the Turn Off delay for Outlet Bank 1 Choose between 0 and 10 seconds Satel...

Page 7: ...that locks up Diagnostic Lights The MAX 5410 is loaded with special features to save your connected equipment from many different forms of dangerous power disturbances Six diagnostic lights on the fr...

Page 8: ...ncoming voltage from the wall receptacle and provides a visual representation of the available power The voltmeter is ALWAYS ON and indicates the incoming line voltage even during an unsafe voltage co...

Page 9: ...lide switch located on the rear panel controls the timing Together these outlets can be set as Always On or with a turn off delay of 10 seconds to prevent speak er thump This switch provides the optio...

Page 10: ...f the MAX 5410 s switched and high current outlets An AC adapter of the appropriate voltage plugged into a switched outlet on the receiver may also be used if a 12V trigger is not built in The MAX 541...

Page 11: ...ss than 1dB of signal loss throughout the entire 950Mhz to 2 2Ghz range SignalPerfect Telephone Line Protection Satellite TV receivers require a telephone line connection for Pay Per View services The...

Page 12: ...to a safe level 1 Disconnects power to all connected equipment 2 Unsafe Voltage LED is activated and will blink once per second during the unsafe voltage condition The MAX 5410 requires line voltage...

Page 13: ...0V Protection Modes L N L G N G Initial Clamping Level 200V Peak 141V Rms Response Time 1ns Joule Rating 2325 Joules Peak Impulse Current 91 000A Catastrophic Surge Circuit YES AC Line Voltage 120VAC...

Page 14: ...to be repaired or replaced Please refer to the preceding section on Contacting Panamax or the warranty documentation for more information What is the difference between a Surge and Spike A spike is a...

Page 15: ...a MAINACON if all outlets main relay are ON b MAINACOFF if all outlets are OFF c SWITCHEDON if the switched outlets are ON d SWITCHEDOFF if the switched outlets are OFF e HICURRENTON if the high curre...

Reviews: