background image

Installing the water heater.

This water heater must be installed in accordance with these instructions, local codes, utility company

requirements, and/or in the absence of local codes, use the latest edition of the American National

Standard/National Fuel Gas Code. A copy can be purchased from either the American Gas Association,

400 North Capitol Street Northwest, Washington, DC  20001 as ANSI standard Z223.1 or National Fire

Protection Association, 1 Batterymarch Park, Quincy, MA 02269 as NFPA 54.  In Canada, the latest

edition of the CSA B149.1 Natural Gas and Propane Installation, and the Canadian Electrical Code,

CSA C22.1 Part 1, in the absence of local codes.

Location

The water heater should not be located
in an area where leakage of the heat
exchanger or connections will result in
damage to the area adjacent to it or to
lower floors of the structure. 

When such areas cannot be avoided it is
recommended that a suitable catch pan,
adequately drained, must be installed
under the water heater.

The pan must not restrict combustion
air flow.

A gas fired water heater or any other
appliance should not be installed 
in a space where liquids which give off
flammable vapors are to be used or stored.
Such liquids include gasoline, LP gas
(butane or propane), paint or adhesives and
their thinners, solvents or removers.

Because of natural air movement in a
room or other enclosed space, flammable
vapors can be carried some distance from
where their liquids are being used or
stored. The open flame of the water
heater’s main burner can ignite these
vapors causing an explosion or fire which
may result in severe burns, death or
property damage.

The water heater must be located so it is
not subject to physical damage, for example,
by moving vehicles, area flooding, etc. 

If the water heater is installed in a garage,
it should be installed so that the direct
ignition system and main burner are no
less than 18 inches above the garage floor.

Raising the gas fired water heater will
reduce BUT NOT eliminate the possibility
of lighting the vapor of any flammable
liquids which may be improperly stored or
accidentally spilled.

The water heater should be installed as
close as practical to the vent termination
to minimize vent length and the number
of elbows required for venting.

The water heater should be installed
with the proper venting materials and
termination suitable for Category III
venting.

Failure to install and properly venting
the water heater to the outdoors as
outlined in the Venting Section of this
manual can result in unsafe operation.

Long hot water lines should be insulated
to conserve water and energy. 

The water heater and water lines should
be protected from exposure to freezing
temperatures.

Do not 

install the water heater in

bathrooms, bedrooms, any occupied
rooms normally kept closed, or in
outdoor areas.

Do not

install the water heater in small,

poorly ventilated rooms, or in air tight
rooms with air-conditioning.

Do not

install water heater where

subject to vibrations.

Do not

install the water heater in

Recreational Vehicles, Mobile Homes,
Boats and other Watercrafts.

Do not

install the water heater near

vents for heating or cooling.

Minimum clearance from combustible
construction is 1/2” sides, 0” rear (with
support bracket); 12” from the bottom;
12” from the front of the water heater;
and 12” from the top (24” from front
and top is recommended for servicing
purposes). Maintain a minimum
clearance of 2” around the vent pipe to
combustible construction. If the
clearances stated on the
Instruction/Warning Label, located on
the front panel of the heater differ,
install the water heater according to the
clearances stated on the label.

7

WARNING: Combustible

construction refers to

adjacent walls and ceilings

and should not be confused

with combustible or

flammable products and

materials. Combustible

and/or flammable products

and materials should never

be stored in the vicinity of

this or any gas appliance.

!

min.

1/2 "

min.

1/2 "

min. 12"

(24" minimum is
recommended for service)

Top = 12"
Vent = 2"
Front = 12"

min. 2"

min. 2"

Back = 0" (with support bracket)
Side = 1/2"
Bottom = 12"

Minimum Clearance

from

Combustible Construction

Vent Pipe

3" min

2" min

2" min

Summary of Contents for PH-28RIFSN

Page 1: ...installation and adjustment of the water heater and two to the owner operator to explain the features operation safety precautions maintenance and troubleshooting of the water heater This manual also...

Page 2: ...READ THIS MANUAL FOR YOUR RECORDS Write the model and serial numbers here You can find them on a label on the appliance Staple sales slip or cancelled check here Proof of the original purchase date is...

Page 3: ...hesives solvents paint thinners etc and the vapors they produce are extremely dangerous DO NOT handle use or store gasoline or other flammable or combustible materials anywhere near or in the vicinity...

Page 4: ...water temperature is recommended to reduce the risk of scald injury Contact a licensed plumber or the local plumbing authority for further information Notice The factory setting allows operating tempe...

Page 5: ...r LP gas must be used with great caution It is heavier than air and will collect first in lower areas making it hard to detect at nose level Before attempting to light the water heater make sure to lo...

Page 6: ...ALL INSTRUCTIONS BEFORE USING WARNING For your safety the information in this manual must be followed to minimize the risk of fire or explosion electric shock or to prevent property damage personal i...

Page 7: ...reduce BUT NOT eliminate the possibility of lighting the vapor of any flammable liquids which may be improperly stored or accidentally spilled The water heater should be installed as close as practica...

Page 8: ...warranty is voided when failure of the heater is due to operation in a corrosive atmosphere NOTICE The water heater should not be installed near an air supply containing halogenated hydrocarbons Inspe...

Page 9: ...water supply lines DO NOT cover the drain valves To ensure proper operation of the water heater the following water pressure guidelines should be followed Operation of the water heater requires the mi...

Page 10: ...ter damage Notice If the relief valve on the system discharges periodically a problem exists and service to the water system is required Water Supply Connections Continued Install a shutoff valve near...

Page 11: ...be installed at the gas connection of the water heater at the time of installation see diagram to the left The branch gas supply line to the water heater should be clean 3 4 black steel pipe or other...

Page 12: ...air supply for proper operation as outlined in the Venting section of this manual WARNING Use UL approved Category III Stainless Steel vent material only No other vent material is permitted WARNING Re...

Page 13: ...tructions before installation Test fit the adapter over the water heater collar before proceeding Adjust clamp as needed With an alcohol wipe clean inside surface A of adapter and outside surface of B...

Page 14: ...Not terminate vent pipe directly on brick or masonry surfaces Use a rust resistant sheet metal backing plate 2 x 2 feet behind vent See illustration Do Not locate vent terminal too close to shrubbery...

Page 15: ...board or other composite material Use 4 10x1 1 4 wood screws for plywood solid wood sheathing or members Use suitable masonry anchors when passing through solid masonry walls Reinstall the decorative...

Page 16: ...f condensate in accordance to local codes Rain Cap Storm Collar Support Clamp 1 4 per foot downward slope 2 Max Chase Requires 6 Clearance to Combustibles Firestop Firestop Roof Jack Adjustable Roof F...

Page 17: ...tween the water heater and the remote control s installation location is limited to 195 feet of wire NOTICE Only one of each type of remote controls can connect to the water heater Therefore a maximum...

Page 18: ...upwards Connect the remote control cables to the extension cable from the water heater Place the remote control over the base plate Ensure the projections in the base plate fit into the housings in t...

Page 19: ...W BR AIR INTAKE FILTER SWITCH TRANSFORMER GND BK GND WATER FLOW SENSOR OVER HEAT LIMITER BK BLACK COLOUR CODE BR BROWN R RED W WHITE B BLUE GY GRAY GR GREEN O ORANGE Y YELLOW G Y GREEN YELLOW REMOTE...

Page 20: ...liance Shut off supplied Sediment Trap Manual Gas Supply Line Shut off Valve Union Cap Cold Water Supply Shut off Valve Check Valve Vent Adapter F PRIORITY POWER ON OFF Remote Control Power Supply Cor...

Page 21: ...er Hot and Cold Pipe Insulation Installation Gas Inlet Check Valve Inlet Pipe Cold Water Hot Water Insulate all the way to the top Insulation Blankets Insulation blankets available to the general publ...

Page 22: ...Supply Gas type matches rating plate Gas supply pressure is sufficient for the water heater Gas line equipped with shut off valve union and sediment trap Approved pipe joint compound used Soap and wa...

Page 23: ...s label 2 Turn off all electric power to the appliance 3 Do not attempt to light the burner by hand 4 Turn the Gas Shutoff Valve located on the outside of the unit clockwise to the OFF position 5 Wait...

Page 24: ...educing point of use water temperature by mixing hot and cold water in branch water lines Contact a licensed plumber or the local plumbing authority for further information See page 4 for more details...

Page 25: ...ter Always remember to test the water temperature with your hand before use and remember that hotter water increases the risk of scald injury Always supervise young children or others who are incapaci...

Page 26: ...ice After inspection maintenance and or cleaning ensure proper operation by turning on a hot water faucet Housekeeping Before performing Housekeeping tasks to this water heater turn the unit off and d...

Page 27: ...be turned off The water heater and piping should be drained if they might be subjected to freezing temperatures After a long shut down period the water heater s operation and controls should be check...

Page 28: ...ns for draining water out of the water heater Turn off the switch on the remote control Close the gas shut off valve s Unplug the power supply cord or disconnect breaker at least 10 seconds after step...

Page 29: ...etely The main burner goes off when incoming water volume is inadequate Check that proper power is being supplied and or water supply is adequate Fan continues to rotate after hot water faucet is clos...

Page 30: ...t water faucet once The water heater can then be used The Gas Shutoff Valve is not opened completely Gas Service has been interrupted LP Gas is running low LP models only Contact Gas Utility Company F...

Page 31: ...ls using natural or LP gas Instructions For Placing a Parts Order Address parts orders to the distributor or store from where the water heater was purchased All parts orders should include The model a...

Page 32: ...all of the other component parts warranty will be limited to one 1 year from the Effective Date WARRANTY EXCLUSIONS This Limited Warranty will not cover a Service trips to your home to teach you how t...

Page 33: ...ines that a defect exists Paloma shall furnish replacement part s in full settlement of its warranty obligations Purchasers shall be required to return at purchasers expense the defective part s to th...

Page 34: ...140 F With Main Control Dip Switch Combustion System Fan Assisted Combustion Main Burner Bunsen Type Burner Ignition Electric Continuous Sparking Ignition Electric Portion Electric Rating 120 VAC 60Hz...

Page 35: ...This page was intentionally left blank...

Page 36: ...Paloma Industries Inc 2151 Eastman Avenue Oxnard CA 93030 PRINTED IN JAPAN 31 50641...

Reviews: