Palmgren 81093 Operating Manual & Parts List Download Page 4

4

ASSEMBLY (CONTINUED)

Slide disc table with attached trunnions onto the raised bosses
on each side of disc guard. Mount two handles and flat washers
through trunnions into threaded holes on each side of disc
guard.

Locate table in desired position and secure with handles.

Be sure the gap between the disc and disc table is 

1

/

16

” or less.

If adjustment is necessary, loosen set screw in aluminum disc
through the opening at top-rear of disc guard. Position disc 

1

/

16

or less from edge of table. Secure disc with set screw.

ASSEMBLE BELT TABLE

Refer to Figure 8, page 8.

Slide belt table assembly (Ref. No. 76) into trunnion groove of pivot
bracket (Ref. No. 47). Mount using socket head bolt and flat washer
(Ref. Nos. 2 and 75). Locate table in desired position. Be sure that
gap between belt table and belt is 

1

16

” or less. Tighten bolt securely.

INSTALLATION

Refer to Figures 5, 6 and 7.

WARNING:

All electrical connections must be performed by a

qualified electrician.

POWER SOURCE

The motor is designed for operation on the voltage and frequency
specified. Normal loads will be handled safely on voltages not
more than 10% above or below the specified voltage.

Running the unit on voltages which are not within the range may
cause overheating and motor burnout. Heavy loads require that
voltage at motor terminals be no less than the voltage specified on
nameplate. Power supply to the motor is controlled by a single
pole locking rocker switch. Remove the key to prevent 
unauthorized use.

GROUNDING INSTRUCTIONS
WARNING:

Improper connection of equipment grounding con-

ductor can result in the risk of electrical shock. Equipment should
be grounded while in use to protect operator from electrical
shock.

Check with a qualified electrician if grounding instructions are
not understood or if in doubt as to whether the tool is properly
grounded.

This tool is equipped with an approved 3-conductor cord rated
at 300V and a 3-prong grounding type plug (See Figure 5) for
your protection against shock hazards.

Grounding plug should be plugged directly into a properly
installed and grounded 3-prong grounding-type receptacle, as
shown (Figure 5).

Do not remove or alter grounding prong in any manner. In the
event of a malfunction or breakdown, grounding provides a
path of least resistance for electrical shock.

WARNING:

Do not permit fingers to touch the terminals of plug

when installing or removing from outlet.

Plug must be plugged into matching outlet that is properly
installed and grounded in accordance with all local codes and
ordinances. Do not modify plug provided. If it will not fit in out-
let, have proper outlet installed by a qualified electrician.

Inspect tool cords periodically, and if damaged, have repaired
by an authorized service facility.

Green (or green and yellow) conductor in cord is the grounding
wire. If repair or replacement of the electric cord or plug is nec-
essary, do not connect the green (or green and yellow) wire to
a live terminal.

Where a 2-prong wall receptacle is encountered, it must be
replaced with a properly grounded 3-prong receptacle installed
in accordance with National Electric Code and local codes and
ordinances.

WARNING:

This work should be performed by a qualified 

electrician.

A temporary 3-prong to 2-prong grounding adapter (See
Figure 6) is available for connecting plugs to a two pole outlet
if it is properly grounded.

Do not use a 3-prong to 2-prong grounding adapter unless
permitted by local and national codes and ordinances.

(A 3-prong to 2-prong grounding adapter is not permitted in
Canada.) Where permitted, the rigid green tab or terminal on
the side of the adapter must be securely connected to a per-
manent electrical ground such as a properly grounded water
pipe, a properly grounded outlet box or a properly grounded
wire system.

Many cover plate screws, water pipes and outlet boxes are not
properly grounded. To ensure proper ground, grounding means
must be tested by a qualified electrician.

EXTENSION CORDS

The use of any extension cord will cause some drop in voltage
and loss of power.

Wires of the extension cord must be of sufficient size to carry
the current and maintain adequate voltage.

Running the unit on voltages which are not within ±10% of the
specified voltage may cause overheating and motor burn-out.

Use the table to determine the minimum wire size (A.W.G.)
extension cord.

Use only 3-wire extension cords having 3-prong grounding
type plugs and 3-pole receptacles which accept the tool plug.

Palmgren Operating Manual & Parts List

81093

Figure 5 – 3-Prong Receptacle

Properly Grounded Outlet

Grounding Prong

3-Prong Plug

Figure 6 – 2-Prong Receptacle with Adapter

Grounding Lug

Adapter

3-Prong Plug

2-Prong Receptacle

Make sure this is 
Connected to a known
Grounded Receptacle

Figure 4 – Assemble Disc Table

End Shield

Flat Washers

Trunnion

Disc Table

Disc Guard

Dust Chute

Set Screw

Handle

Armature and Key

Aluminum Disc
with Abrasive
Disc

Summary of Contents for 81093

Page 1: ...operating manual parts list 81093 6 x 9 BELT DISC SANDER WITH STAND Read carefully and follow all safety rules and operating instructions before first use of this product 35355 00 08 12...

Page 2: ...ify all parts before attempting assembly Refer to Figure 2 A Top Frame 4 B Brace 4 C Leg 4 D Rubber Foot 4 E 5 16 18 x 5 8 Carriage Bolt 32 F 5 16 18 Hex Nut 32 G 5 16 Flat Washer 32 SPECIFICATIONS Be...

Page 3: ...us injury could occur if tool is tipped or if belt or disc are unintentionally contacted Know your tool Learn the tool s operation application and specific limitations Handle workpiece correctly Prote...

Page 4: ...lug when installing or removing from outlet Plug must be plugged into matching outlet that is properly installed and grounded in accordance with all local codes and ordinances Do not modify plug provi...

Page 5: ...eep your hands clear of abrasive belt disc and all moving parts For optimum performance do not stall motor or reduce speed Do not force the work into the abrasive Support workpiece with belt table whe...

Page 6: ...adjustable from 0 to 45 for beveled work To adjust the disc table loosen the two handles Ref No 1 and pivot to the desired angle Use the scale on disc table trunnions to set table from 0 to 45 from a...

Page 7: ...t line voltage 4 Incorrect fuses or circuit breakers in power line 5 Motor overloaded Applying too much pressure to workpiece Not tracking properly CORRECTIVE ACTION 1 If fuse is blown replace with fu...

Page 8: ...4 5 76 61 64 65 7 67 68 69 72 7 71 70 66 70 73 75 2 74 42 7 41 40 43 12 44 37 45 35 36 37 38 39 31 33 34 32 23 22 10 30 29 27 28 24 25 26 25 24 23 22 10 18 21 7 20 19 17 18 16 15 14 48 47 79 38 49 41...

Page 9: ...20mm Socket head bolt 6 38 8mm Lock washer 5 39 Abrasive belt 22173 00 1 40 Lower belt guard 36339 00 1 41 8 1 25 x 12mm Set screw 7 42 Miter gauge assy 36340 00 1 43 Drive drum 08391 00 1 44 Pivot s...

Page 10: ...ardware item available locally 1 Top frame 36351 00 4 2 Brace 36352 00 4 3 Leg 36353 00 4 4 Foot 36354 00 4 5 5 16 18 x 5 8 Carriage bolt 32 6 5 16 Flat washer 40 7 5 16 18 Hex nut 36 8 5 16 18 x 2 He...

Page 11: ...Palmgren Operating Manual Parts List 81093 11 NOTES...

Page 12: ...Work stands 2 years Arbor presses 2 years Metal forming equipment 2 years Accessories 1 year The obligation of Palmgren is limited solely to the repair or replacement at our option at its factory or...

Page 13: ...e la mesa de la correa G Conjunto de la gu a de ingletes La bolsa de partes incluye dos manijas tres tornillos de cabeza de arandela de 1 4 20 x 1 2 pulg dos tornillos de cabeza de arandela 10 24 x 3...

Page 14: ...a la herramienta lubricada y limpia de modo que funcione de la manera m s segura Retire las herramientas de ajuste Desarrolle el h bito de verificar que hayan sido retiradas las herramientas de ajuste...

Page 15: ...onar al voltaje y frecuencia especifica dos Las cargas normales se pueden manejar con seguridad con voltajes no mayores de 10 por encima o por debajo del voltaje especificado Si se hace funcionar la u...

Page 16: ...lectricista calificado vuelva a cablear el motor e instale un enchufe de tres puntas de 240 voltios y 15 amperios en el cord n de alimentaci n de la esmeriladora OPERACION Consulte la Figura 8 p gina...

Page 17: ...andela plana Refs No 2 y 75 sosteniendo la mesa de la correa en el soporte de pivote Desinstale la mesa de la correa Monte el tope de seguridad en el soporte de pivote utilizando el perno de cabeza hu...

Page 18: ...e Use agua y jab n para limpiar las piezas pintadas las piezas de goma y los protectores de pl stico LUBRICACION Los rodamientos de bola protegidos son permanentemente lubricados en la f brica No requ...

Page 19: ...a diferente 4 Fusibles o cortacircuitos incorrectos en la l nea de alimentaci n 5 Motor sobrecargado Se est aplicando demasiada presi n a la pieza de trabajo Alineamiento incorrecto MEDIDA CORRECTIVA...

Page 20: ...de acabado 2 a os Sierras de banda 2 a os Plataformas de soporte 2 a os Prensas de husillo 2 a os Equipos de formado met lico 2 a os Accesorios 1 a o La obligaci n de Palmgren est limitada nicamente...

Reviews: