Pag.: 59/60
Cod. 004770370
TC120
5.0 USER’ S MENU
It allows the optimisation of the functioning system.
The list of the available user’s menu changes according to the selected configuration system.
Table 4 shows the list of the parameters and configurations .
To enter the MENU push the button for about 5 seconds
The display changes.
To show the user’s parameters labels push
To show the value of the user’s parameter push
To modify the value of the user’s menu push
To show the list and save the user’s parameter push button
To show the user’s parameters list without modifying push button
To exit the menu wait about 5 seconds or use the button
System’s configuration
Parameter
1 2 3 4 5 6 7 8
Description
U. Min Default Max
A01
x x x x x x
x
Thermostat on Probe1
°C
20
50
70
A03
x
x x
Differential Thermostat Probe1 - Probe2
°K
0
4
20
A04
x x
x x
Thermostat on Probe2
°C
20
60
80
A05
x x
Thermostat on Probe2
°C
50
55
80
A06
x
Maximum Thermostat on Probe1
°C
60
65
90
I01
x x x x x x
x
Thermostat hysteresis parameter
A01
°K
0
2
5
I03
x
x x
Thermostat hysteresis parameter
A03
°K
0
2
5
I04
x x
x x
Thermostat hysteresis parameter
A04
°K
0
2
5
I05
x x
Thermostat hysteresis parameter
A05
°K
0
2
5
I06
x
Thermostat hysteresis parameter
A06
°K
0
2
5
t 01
x
x
Timer
min
0
20
25
Table
4 –
Description USER’S menu
Thermostats:
The outputs turns on at the reaching of the thermostat’s value and turns off at the reaching of the thermostat’s value minus
the related hysteresis value.
6.0 USE MANUAL AND MAINTENANCE
6.1 CONTROL BOARD DESCRIPTION
ON/OFF:
The ON/OFF of the controller is with the long push of the button
The state
OFF is signalled with the led L4.
Before turning on the fire make sure the controller is on.
Do not turn the controller off during the fireplace’s working
and before the fire is off and the embers are on.
In case of black out do not turn on or load the fireplace. .
At all the controller’s feeding a control is done and appears “
ChC
”.
TEMPERATURE Visualization:
the display shows the temperature of the Probe1,
signalled by a segment on the display above on the right .
Through the button it is possible to chose the temperature of the Probe2 signalled by a segment below on the display
on the right.
SPARK Function
Could be activated according to the type of the fireplace.
Pushing the button the spark kit is activated:
The display shows ‘
Sci’
for 2 seconds.
For all the functioning length the led is on.
6.2 ADDITIONAL FUNCTIONS
STANDBY Function:
If the device is
OFF, if the fireplace is hot (temperature more than
A10
)
The device starts
ON.
ANTIBLOCK Program
PUMP
AUX
: if activated installer’s parameter P02 = 1
In case of inactivity of the outputs
PUMP/AUX for time more than
T02
(Timer Anti block: 24 h) calculated also in case
of device OFF
The Outputs are activated for time as
T03 [20 sec]
The relative led is ON
L1/L3 and the display shows
bLP
.
MENU
MENU
MENU