66
004778560 - 17/11/2020
LINDA
LINDA 9
LINDA 12
Min
Max
Min
Max
Overall thermal power (output)
kcal/h 3095,44 7738,61 3095,44 10318,14
kW
3,6
9
3,6
12
Yield
%
90,4
90,9
90,4
89,6
Flue gas temperature
°C
103,9
149,6
103,9
187,9
Flue gas flow rate
g/s
4,52
6,56
4,52
7,81
Hourly fuel consumption
kg/h
0,8
2,07
0,8
2,78
CO emissions (at 13% O2)
mg/
Nm
3
157
17
157
22
Flue gas outlet
mm
Ø 80
Outside air intake
mm
Ø 60
Fuel
Wooden pellets
Flue draught
Pa
12 (±2)
Minimum draught for chimney sizing
Pa
0,0
Stove suitable for rooms no smaller than
m
3
30
30
Feeding tank capacity
kg
22
Weight
kg
190
No. rear fans
no.
1 (Pro 2)
2 (Pro 3)
Rear fan flow rate
m
3
/h
140
140
Electrical data
LINDA 9
LINDA 12
Voltage
V
230
Frequency
Hz
50
Max power absorbed during operation
W
70
Power absorbed at electric ignition
W
370