Children must not play with the ap-

pliance. Cleaning for which the user is 

responsible must not be carried out by 

unsupervised children.
Before performing any type of opera-

tion, the user or whoever is operating 

the product must have read and fully 

understood the contents of this instal-

lation and use manual. Errors or bad 

settings may cause hazardous condi-

tions and/or irregular operation.
Unskilled users must be protected from 

access to any part that could expose 

them to danger. Therefore, they must 

not be allowed to intervene on internal 

parts at risk (electrical or mechanical), 

even if the disconnection of the power 

supply is required.
Respect the instructions and warnings 

highlighted on the sign plates dis-

played on the appliance.
The sign plates are accident prevention 

devices, therefore they must always be 

perfectly legible. If these are damaged 

and unreadable, it is mandatory to 

replace them, requesting the original 

spare parts from the Manufacturer.
Follow the routine and extraordinary 

maintenance schedule carefully.
Do not use the appliance without 

having first carried out daily cleaning.
Do not use the appliance if operation is 

abnormal, you suspect a breakage or if 

there are unusual noises.
In case of failure or malfunction, turn 

the appliance off and immediately con-

tact your specialised technician.
Do not throw water on the appliance 

in operation or to extinguish the fire in 

the burn pot.
Do not switch the appliance off by 

disconnecting the mains electrical 

connection.
Do not lean on open doors, this could 

compromise the stability of the 

appliance.
Do not use the appliance as an anchor 

support of any kind.
It is prohibited to use the product as a 

ladder or support structure.
Do not clean the appliance until the 

structure and ashes have completely 

cooled.
Only touch the door when the appli-

ance is cold.
In case of flue gas leaks in the room or 

explosions detrimental to the device, 

turn it off, ventilate the room and im-

mediately contact your installer/service 

technician.
In case of fire in the chimney flue, turn 

the appliance off, disconnect it from 

the power supply and do not open 

the door. Then call the competent 

authorities.
In case of failure of the ignition system, 

do not ignite the appliance with flam-

mable materials.
In electrically powered devices, if un-

burned gas/fumes accumulate inside 

the fire box, do not disconnect the 

electrical power supply and move as far 

away from the appliance as possible.
In case of malfunction of the appliance 

due to a poor flue draught, clean the 

flue in accordance with the procedure 

described in section "10.1 Maintenance 

of the smoke system" on page 91.
Do not touch the painted parts during 

operation to avoid damage to the 

paintwork.
All responsibility for improper use of 

the product is fully borne by the user, 

who relieves the manufacturer of any 

civil and criminal liability.

Summary of Contents for LINDA US 9

Page 1: ...USE AND MAINTENANCE MANUAL This manual is an integral part of the product Read the instructions carefully before installing servicing or operating the product Translation of the original instructions...

Page 2: ...ke to thank you for having purchased one of our products and congratulate you on your choice To make sure you get the most out of your product please carefully follow the instructions provided in this...

Page 3: ...i di ricambio 7 1 11 Targhetta matricola 7 1 12 Consegna dell apparecchio 7 2 AVVERTENZE PER LA SICUREZZA 8 2 1 Avvertenze per l installatore 8 2 2 Avvertenze per il personale tecnico addetto alla man...

Page 4: ...io 37 7 5 Circolazione dell aria canalizzata 37 7 6 Installazione pareti refrattarie 38 7 7 Collegamento elettrico 40 7 8 Ottimizzazione della combustione 40 8 CONFIGURAZIONE INIZIALE 41 8 1 Configura...

Page 5: ...del manuale quello di fornire le regole fondamentali e di base per una corretta installa zione dell apparecchio La scrupolosa osservanza di quanto in esso de scritto garantisce un elevato grado di sic...

Page 6: ...ono conformi alle disposizioni legislative delle seguenti direttive comunitarie 2014 30 UE Direttiva Compatibilit Elettromagnetica 2014 35 UE Direttiva Bassa Tensione 2017 2102 UE Direttiva RoHS 2009...

Page 7: ...a incidenti causati proprio dalla rot tura improvvisa dei componenti che potrebbero provocare gravi danni a persone e cose 1 11 Targhetta matricola La targhetta matricola A posta nella parte posterior...

Page 8: ...a tutti i regolamenti di sicurezza locali nazio nali ed europei L apparecchio dovr essere installato su pavimenti con adeguata capacit portante Verificare che le predisposizioni della canna fumaria e...

Page 9: ...ollegate e per prevenire incidenti si devono sempre osservare le indicazioni riportate nel presente manuale L apparecchio presenta delle superfici esterne particolarmente calde porta maniglia vetro tu...

Page 10: ...cnico specializzato Non gettare acqua sull apparecchio in funzionamento o per spegnere il fuoco nel braciere Non spegnere l apparecchio scollegan do la connessione elettrica di rete Non appoggiarsi su...

Page 11: ...unit e guastare gli isolamenti elettrici provocando scosse elettriche Non sostare per un lungo periodo da vanti al prodotto in funzione Unusoerratodelprodottoouninterven to di manutenzione scorretto...

Page 12: ...eve restare chiuso durante il funzionamento dell apparecchio vietato usare l apparecchio come in ceneritore di rifiuti 3 2 Stoccaggio del pellet II pellet deve essere conservato in un ambiente asciutt...

Page 13: ...7 6 9 10 11 12 1 2 3 4 5 Fig 3 1 Porta estetica 2 Vetro porta estetica 3 Vetro porta tecnica 4 Maniglia di apertura 5 Porta tecnica focolare 6 Ventilatore ambiente 7 Cassetto cenere 8 Braciere 9 Micro...

Page 14: ...INDA US LINDA US PRO 2 7 6 6 4 5 2 3 1 4 5 2 3 1 Fig 4 1 Cavo di alimentazione 2 Termostato a riarmo manuale 3 Interruttore di accensione 4 Tubo aria comburente 5 Connettore RJ11 6 Tubo di uscita fumi...

Page 15: ...INDA PRO 2 PRO 3 4 5 6 6 8 2 3 7 1 4 5 2 3 1 Fig 5 1 Cavo di alimentazione 2 Termostato a riarmo manuale 3 Interruttore di accensione 4 Tubo aria comburente 5 Connettore RJ11 6 Tubo di uscita fumi 7 V...

Page 16: ...4 2 Dimensioni LINDA US 1259 1206 80 130 80 589 213 375 634 618 47 130 ingresso aria 80 uscita fumi solo per versioni PRO2 1239 20 310 526 301 130 ingresso aria 80 uscita fumi solo per versioni PRO2...

Page 17: ...0 17 1259 1206 80 80 60 80 589 213 162 634 618 47 60 ingresso aria 80 uscita fumi solo per versioni PRO2 PRO3 1239 20 310 526 301 213 251 218 120 PRO3 PRO2 60 ingresso aria 80 uscita fumi solo per ver...

Page 18: ...ni di CO al 13 di O2 mg Nm3 114 28 114 35 Uscita fumi mm 80 Presa d aria esterna mm 130 Combustibile Pellet di legno Tiraggio della canna fumaria Pa 12 2 Tiraggio minimo per dimensionamento del camino...

Page 19: ...CO al 13 di O2 mg Nm3 157 17 157 22 Uscita fumi mm 80 Presa d aria esterna mm 60 Combustibile Pellet di legno Tiraggio della canna fumaria Pa 12 2 Tiraggio minimo per dimensionamento del camino Pa 0 0...

Page 20: ...ratura fumi Tf C Distanza minima da materiali infiammabili X1 X2 Y mm Tensione V V Frequenza f Hz Potenza max assorbita in funzionamento Wmin W Potenza max assorbita in accensione Wmax W Leggere e seg...

Page 21: ...1 T04 Pa Pa T03 T02 T01 T05 I03 GND GND GND I04 5V 16V F02 F03 F01 I02 220 240 Vac 20 ext 3 4 ext 1 2 Solo nei modelli con microinterruttori sulla portina o sul coperchio serbatoio Only where microswi...

Page 22: ...01 I02 L 220 240 N 220 240 Vac PE L N BROWN BLUE GREEN RED BLACK BLUE 1 4 t t K 3 ext 1 2 Fig 10 1 Sensore di hall 2 Termostato esterno 3 Sonda ambiente 4 Sonda pellet 5 Sonda fumi 6 Differenziale di...

Page 23: ...elli ventilatore con condensatore Only in models with a condenser room fan Solo nei modelli con microinterruttori sulla portina o sul coperchio serbatoio Only where microswitches are provided Fig 11 1...

Page 24: ...ti in legno o parquet per evitare che il peso dell apparecchio possa rovinarli duran te lo spostamento 5 MOVIMENTAZIONE E TRASPORTO L apparecchio viene consegnato completo di tutte le parti previste F...

Page 25: ...arsi della loro qualifica e delle loro reali capacit Per l Italia tali tecnici devono essere in possesso di abilitazione alla lettera C rilasciata dalla camera di commercio in base al D M 37 08 6 3 Lu...

Page 26: ...a Il costruttore declina ogni responsabilit per eventuali variazioni delle caratteristiche del mate riale costituente il pavimento sotto la protezione Prevedere uno spazio tecnico accessi bile per le...

Page 27: ...gui Fig 22 Fig 23 Prelievo dell aria comburente dall esterno In questo caso possibile in alternativa canalizzare l aria comburente sfruttando un tubo di scarico coassiale per l espulsione dei fumi e i...

Page 28: ...l appa recchio sia libero di prelevare aria in ambiente avendo cura di collegare sul tubo di ingresso dell aria il tratto di tubo corrugato qualora venga fornito fissandolo con la fascetta e piegando...

Page 29: ...ione causati dalla scarsit di aria comburente 6 5 Raccordo fumi L apparecchio funziona con la camera di combu stione in depressione pertanto indispensabile assicurarsi che lo scarico dei fumi sia a te...

Page 30: ...le all uscita dello scarico fumi dell apparecchio necessario collegare in basso un tubo per l evacuazione dell eventuale condensa che pu formarsi nel camino Fig 26 Fig 26 SOLO PER LINDA US A livello d...

Page 31: ...mensioni che per i materiali utilizzati nella sua costruzione Lo scarico dei fumi attraverso un camino tradizio nale Fig 28 Fig 29 pu essere fatto purch ci si assicuri sullo stato di manutenzione del...

Page 32: ...collegamento al camino in mu ratura sia opportunamente sigillato In caso di passaggio dei tubi attraverso tetti o pareti in legno si consiglia di uti lizzare appositi kit di attraversamento certificat...

Page 33: ...NDA US possibile installare la stufa in diversi modi in base alle proprie esigenze Tubo coassiale Tubo monoparete e ripresa aria in ambiente Tubo monoparete e ripresa aria collegata all e sterno 7 2 1...

Page 34: ...monoparete e ripresa aria collegata all esterno In questo caso l aria comburente verr presa di rettamente dall esterno dal posteriore della stufa Smontare lo schienale della stufa A Scollegare il tub...

Page 35: ...azioni installative LINDA possibile installare la stufa in diversi modi in base alle proprie esigenze Tubo monoparete e ripresa aria in ambiente Tubo monoparete e ripresa aria collegata all e sterno 7...

Page 36: ...iere il silenziatore B Togliere il pretranciato C sullo schienale A e far passare il tubo flessibile D per collegarlo ad una presa d aria esterna Fig 37 Stringere il tubo D con la fascetta metallica E...

Page 37: ...ndo la stufa viene utilizzata per riscaldare due o pi locali adiacenti indispensabile favori re il ricircolo dell aria ambiente per uniformare la temperatura nelle varie stanze Per la canalizzazione d...

Page 38: ...nalit neces sario che la ventilazione dei ventilatori destro e sinistro sia impostata su ON Il termostato che comanda il ventilatore destro andr collegato ai morsetti 5 e 6 della morsettiera al posto...

Page 39: ...nserendo la parte inferiore della parete stessa nell apposito allog giamento ricavato sul supporto G Fig 44 G A Fig 44 possibile regolare il supporto H delle pareti refrattarie agendo sulle viti L L H...

Page 40: ...al servizio di assistenza tecnica o da un tecnico qualificato in modo da preve nire ogni rischio Fig 48 obbligatorio che l impianto sia prov visto di messa a terra e di interruttore differenziale in o...

Page 41: ...morsetti e posizionata sul pannello posteriore Fig 49 possibile posizionare la sonda ambiente in un altro locale per rilevare la temperatura dell am biente desiderato Impostare la configurazione 1 per...

Page 42: ...nte quando la tempe ratura scende al di sotto del valore impostato sul termostato esterno circuito chiuso Tale configurazione pu essere utilizzata anche per accendere e spegnere l apparecchio manual m...

Page 43: ...iante ca ricamento automatico 9 2 Primo avvio Durante la prima accensione della stufa mantenere i locali ben arieggiati in quanto si possono generare sgradevo li odori o fumi causati dall evaporazione...

Page 44: ...i pellet bruciato Se esistono dei tratti orizzontali necessario verificare e asportare l eventuale deposito di cenere e fuliggine prima che le stesse otturino il passaggio dei fumi In caso di mancata...

Page 45: ...NA 1 MESE Braciere X Cassetto Vano cenere Fig 57 X Vetro Fig 58 X Griglia ventilatore X Caldaia X 10 3 2Centro di assistenza tecnico abilitato 1 ANNO Guarnizioni porta e braciere X Collettore fumi Fig...

Page 46: ...spazzola con laccio flessibile per pulire il condotto di eva cuazione fumi ed aspirare i residui di cenere A B C Fig 54 10 5 Pulizia condotto di evacuazione fumi LINDA US Si raccomanda di effettuare...

Page 47: ...la cenere dalla camera di combustione perch i sali presenti provocano corrosione del me tallo Inoltre la cenere potrebbe ottu rare il passaggio dell aria variando lo sviluppo della fiamma che nel cas...

Page 48: ...etergenti liquidi o prodotti aggressivi Fig 58 10 8 Pulizia del collettore fumi Dopo aver pulito il braciere toglierlo dalla sua sede e pulire il vano che lo contiene Estrarre il cassetto cenere e asp...

Page 49: ...ed animali Smaltire in modo differenziato il prodotto con sente di evitare possibili conseguenze negative per l ambiente e per la salute e permette di re cuperare i materiali di cui composto al fine...

Page 50: ...nce and maintenance 54 1 10 Spare Parts 54 1 11 Serial identification plate 54 1 12 Delivery of the appliance 54 2 SAFETY WARNING 55 2 1 Warnings for the installer 55 2 2 Warnings for technical mainte...

Page 51: ...nfigurations LINDA 82 7 4 Levelling of the appliance 84 7 5 Circulation of ducted air 84 7 6 Installation of refractory walls 85 7 7 Electrical connection 87 7 8 Fuel optimisation 87 8 INITIAL CONFIGU...

Page 52: ...manual The purpose of this manual is to provide the fundamental and basic regulations for correct installation of the appliance Strict observance of that which is described herein guarantees a higher...

Page 53: ...of the following European directives 2014 30 EU Electromagnetic Compatibility Directive 2014 35 EU Low Voltage Directive 2017 2102 EU RoHS Directive 2009 125 EC Eco Design Requirements for Energy Rel...

Page 54: ...ents break unexpectedly which may cause serious harm to persons and property 1 11 Serial identification plate The serial identification plate A is positioned on the rear Fig 1 and shows all the charac...

Page 55: ...comply with all local national and European safety regulations The appliance must be installed on floors with adequate load bearing capacity Check that the chimney flue and air inlet set ups conform...

Page 56: ...ollow the instruc tions provided in this manual The outer surface of the appliance presents several particularly hot parts door handle glass flue gas pipes etc Contact with these parts must there fore...

Page 57: ...ecialised technician Do not throw water on the appliance in operation or to extinguish the fire in the burn pot Do not switch the appliance off by disconnecting the mains electrical connection Do not...

Page 58: ...he electrical insulation caus ing electric shocks Do not sit stand in front of the product in operation for long periods Incorrect use of the product or incor rect maintenance works may create a serio...

Page 59: ...loading of the pellets and must remain closed while the appliance is operating It is prohibited to use the appliance as an incinerator to burn rubbish 3 2 Pellet storage Pellets must be kept in a dry...

Page 60: ...ption 8 7 6 9 10 11 12 1 2 3 4 5 Fig 3 1 Aesthetic door 2 Aesthetic door glass 3 Technical door glass 4 Opening handle 5 Fire box technical door 6 Room fan 7 Ash drawer 8 Burn pot 9 Pellet hopper clos...

Page 61: ...ISH FRAN AIS 004778560 17 11 2020 61 LINDA US LINDA US PRO 2 7 6 6 4 5 2 3 1 4 5 2 3 1 Fig 4 1 Power cable 2 Manual reset thermostat 3 Power switch 4 Combustion air pipe 5 RJ11 connector 6 Flue gas pi...

Page 62: ...17 11 2020 LINDA LINDA PRO 2 PRO 3 4 5 6 6 8 2 3 7 1 4 5 2 3 1 Fig 5 1 Power cable 2 Manual reset thermostat 3 Power switch 4 Combustion air pipe 5 RJ11 connector 6 Flue gas pipe 7 Rear fan PRO2 8 Re...

Page 63: ...17 11 2020 63 4 2 Dimensions LINDA US 1259 1206 80 130 80 589 213 375 634 618 47 130 ingresso aria 80 uscita fumi solo per versioni PRO2 1239 20 310 526 301 130 air inlet 80 flue gas outlet only for v...

Page 64: ...6 80 80 60 80 589 213 162 634 618 47 60 ingresso aria 80 uscita fumi solo per versioni PRO2 PRO3 1239 20 310 526 301 213 251 218 120 PRO3 PRO2 60 air inlet 80 flue gas outlet only for versions PRO2 PR...

Page 65: ...ourly fuel consumption kg h 0 79 2 02 0 79 2 73 CO emissions at 13 O2 mg Nm3 114 28 114 35 Flue gas outlet mm 80 Outside air intake mm 130 Fuel Wooden pellets Flue draught Pa 12 2 Minimum draught for...

Page 66: ...0 8 2 07 0 8 2 78 CO emissions at 13 O2 mg Nm3 157 17 157 22 Flue gas outlet mm 80 Outside air intake mm 60 Fuel Wooden pellets Flue draught Pa 12 2 Minimum draught for chimney sizing Pa 0 0 Stove sui...

Page 67: ...m3 Polveri alla potenza nominale 13 O2 Dust mg Nm3 Temperatura fumi Tf C Distanza minima da materiali infiammabili X1 X2 Y mm Tensione V V Frequenza f Hz Potenza max assorbita in funzionamento Wmin W...

Page 68: ...6 I01 T04 Pa Pa T03 T02 T01 T05 I03 GND GND GND I04 5V 16V F02 F03 F01 I02 220 240 Vac 20 ext 3 4 ext 1 2 Solo nei modelli con microinterruttori sulla portina o sul coperchio serbatoio Only where micr...

Page 69: ...05 I03 GND GND GND I04 5V 16V F02 F03 F01 I02 L 220 240 N 220 240 Vac PE L N BROWN BLUE GREEN RED BLACK BLUE 1 4 t t K 3 ext 1 2 Fig 10 1 Hall sensor 2 External thermostat 3 Room sensor 4 Pellet probe...

Page 70: ...t 3 2 1 t x e Solo nei modelli ventilatore con condensatore Only in models with a condenser room fan Solo nei modelli con microinterruttori sulla portina o sul coperchio serbatoio Only where microswi...

Page 71: ...ion to protecting wooden flooring or parquet floors in order to avoid possibly ruining them due to the weight of the appliance when moving it 5 HANDLING AND TRANSPORTATION The appliance is delivered c...

Page 72: ...of their qualifica tions and their actual capacity For Italy these technicians must be in possession of the letter C qualifica tion issued by the chamber of com merce based on the Ministerial Decree 3...

Page 73: ...urning residues The manufacturer declines all responsibility for any variations in the characteristics of the mate rial constituting the floor under the protection Set up an accessible technical space...

Page 74: ...ig 22 Fig 23 Extraction of combustion air from outside In this case a possible alternative may be to channel the combustion air using a coaxial pipe to expel the flue gases and extract the air Fig 18...

Page 75: ...ave the appliance to withdraw the room air making sure to connect the section of corrugated pipe on the air inlet pipe if supplied fixing it with the strap and folding it slightly downwards to prevent...

Page 76: ...rks with the combustion cham ber at negative pressure It is therefore essential to make sure that the flue gas evacuation is airtight this is the responsibility of the installer The appliance must be...

Page 77: ...FOR LINDA On the first vertical tee at the flue gas outlet of the appliance a pipe must be connected at the bottom to drain any condensate that may form in the chimney Fig 26 Fig 26 ONLY FOR LINDA US...

Page 78: ...erms of the dimensions and the materials used in its construction The flue gases can be evacuated through a tra ditional chimney Fig 28 Fig 29 provided the good condition and proper maintenance of the...

Page 79: ...30 Fig 31 Make sure that the connection to the brickwork chimney is properly sealed In case of pipes that pass through wooden roofs or walls it is recommend ed to use special certified ducting kits co...

Page 80: ...INDA US The stove can be installed in different ways de pending on personal needs Coaxial pipe Single wall pipe and air intake in room Single wall pipe and outside air intake 7 2 1 Coaxial pipe A coax...

Page 81: ...e flue gas pipe B Fig 33 B A Fig 33 7 2 3 Single wall pipe and outside air intake In this case the combustion air is taken directly from outside from the back of the stove Remove the back panel of the...

Page 82: ...nfigurations LINDA The stove can be installed in different ways de pending on personal needs Single wall pipe and air intake in room Single wall pipe and outside air intake 7 3 1 Single wall pipe and...

Page 83: ...panel of the stove A Remove the silencer B Remove the preform C on the back panel A and insert the flexible hose D to connect it to an outside air intake Fig 37 Tighten the hose D with the previously...

Page 84: ...iameter 80 mm When the stove is used to heat two or more adjacent rooms it is essential to encourage recirculation of the ambient air to uniform the temperature in the various rooms For air ducting pr...

Page 85: ...ermostats To use this function right and left fan ventilation must be set to ON The thermostat that controls the right fan must be connected to terminals 5 and 6 of the terminal board in place of the...

Page 86: ...ting the bottom part of the wall itself in the special slot carved into the support G Fig 44 G A Fig 44 The refractory wall support H can be regulated using the adjustment screws L L H Fig 45 Position...

Page 87: ...be replaced by the technical assistance service or a qualified techni cian in order to prevent any risk Fig 48 It is mandatory that the system is equipped with an earth connection and a differential s...

Page 88: ...ed to the terminals and positioned on the rear panel Fig 49 It is possible to place the room probe in another place to detect the desired room temperature Set configuration 1 to switch the appliance o...

Page 89: ...stove The stove switches back on automatically when the temperature falls below the value set on the external thermostat closed circuit This configuration can also be used to turn the appliance on an...

Page 90: ...th automatic loading 9 2 First start up During the first ignition of the stove make sure the rooms are properly ven tilated as unpleasant odours or fumes may be generated due to the evapo ration or dr...

Page 91: ...llets If there are horizontal sections it is necessary to check and remove any deposits of ash and soot before they obstruct the passage of fumes In the event of failure to clean or inadequate cleanin...

Page 92: ...NED ON EVERY WEEK 1 MONTH Burn pot X Ash drawer compartment Fig 57 X Glass Fig 58 X Fan grille X Chamber X 10 3 2Authorised technical service centre 1 YEAR Door and burn pot gaskets X Smoke collector...

Page 93: ...ct C Clean the duct C and bend B Use a flexible brush to clean the flue gas duct and vacuum any residual ash A B C Fig 54 10 5 Cleaning the flue gas duct LINDA US It is recommended to carry out cleani...

Page 94: ...on chamber because the salts present cause corrosion of the metal In addition the ash could block the pas sage of air varying the development of the flame which if it approaches the glass would increa...

Page 95: ...ot use solvents acids soaps liquid detergents or aggressive products Fig 58 10 8 Cleaning the flue manifold After cleaning the burn pot remove it from its housing and clean the space where it is conta...

Page 96: ...animals The differentiated disposal of the product makes it possible to avoid potentially negative conse quences on the environment and health and also allows recycling of the materials making up the...

Page 97: ...11 Plaque signal tique 101 1 12 Livraison de l appareil 101 2 AVERTISSEMENTS POUR LA S CURIT 102 2 1 Avertissements pour l installateur 102 2 2 Avertissements pour les techniciens pr pos s la maintena...

Page 98: ...de l air canalis 131 7 6 Installation des plaques r fractaires 132 7 7 Branchement lectrique 134 7 8 Optimisation de la combustion 134 8 CONFIGURATION INITIALE 135 8 1 Configuration 1 Sonde ambiante...

Page 99: ...et contenu du manuel Le but de ce manuel est de fournir les r gles fondamentales et de base pour l installation cor recte de l appareil Le respect scrupuleux des indications qui y fi gurent garantit...

Page 100: ...mes aux dispositions l gislatives des direc tives communautaires suivantes 2014 30 UE Directive sur la compatibilit lectromagn tique 2014 35 UE Directive Basse Tension 2017 2102 UE Directive RoHS 2009...

Page 101: ...s accidents d rivants d incidents caus s pr cis ment par la rupture soudaine des composants qui pourrait provo quer de graves dommages aux personnes et aux choses 1 11 Plaque signal tique La plaque si...

Page 102: ...ionaux et europ ens L appareil devra tre install sur des planchers ayant une capacit portante appropri e V rifier que les pr dispositions du conduit de fum e et de l ar riv e d air soient conformes au...

Page 103: ...quipements lectroniques qui y sont connect s et pour pr venir les accidents les instructions donn es dans ce manuel doivent toujours tre respect es L appareil pr sente des surfaces ext rieuresparticul...

Page 104: ...ture ou des bruits insolites En cas de panne ou de dysfonctionne ment teindre l appareil et contacter imm diatement le technicien sp cialis Ne pas jeter d eau sur l appareil pendant son fonctionnement...

Page 105: ...p pareil et endommager l isolation lec trique provoquant un choc lectrique Ne pas rester longtemps devant le pro duit en fonctionnement Une utilisation incorrecte du produit ou un entretien incorrect...

Page 106: ...granul s et il doit rester ferm pendant le fonctionnement de l appareil Il est interdit d utiliser l appareil comme incin rateur de d chets 3 2 Stockage des granul s de bois Les granul s de bois doiv...

Page 107: ...6 9 10 11 12 1 2 3 4 5 Fig 3 1 Porte d corative 2 Vitre porte d corative 3 Vitre porte technique 4 Poign e d ouverture 5 Porte technique foyer 6 Ventilateur ambiant 7 Tiroir cendre 8 Brasero 9 Micror...

Page 108: ...NDA US LINDA US PRO 2 7 6 6 4 5 2 3 1 4 5 2 3 1 Fig 4 1 C ble d alimentation 2 Thermostat r armement manuel 3 Interrupteur d allumage 4 Tube air de combustion 5 Connecteur RJ11 6 Tube vacuation des fu...

Page 109: ...LINDA PRO 2 PRO 3 4 5 6 6 8 2 3 7 1 4 5 2 3 1 Fig 5 1 C ble d alimentation 2 Thermostat r armement manuel 3 Interrupteur d allumage 4 Tube air de combustion 5 Connecteur RJ11 6 Tube vacuation des fum...

Page 110: ...nsions LINDA US 1259 1206 80 130 80 589 213 375 634 618 47 130 ingresso aria 80 uscita fumi solo per versioni PRO2 1239 20 310 526 301 130 arriv e d air 80 vacuation des fum es seulement pour les vers...

Page 111: ...59 1206 80 80 60 80 589 213 162 634 618 47 60 ingresso aria 80 uscita fumi solo per versioni PRO2 PRO3 1239 20 310 526 301 213 251 218 120 PRO3 PRO2 60 arriv e d air 80 vacuation des fum es seulement...

Page 112: ...3 missions de CO 13 de O2 mg Nm3 114 28 114 35 Sortie fum e mm 80 Prise d air externe mm 130 Combustible Granul s de bois Tirage du conduit de fum e Pa 12 2 Tirage minimum pour dimensionnement du po l...

Page 113: ...ns de CO 13 de O2 mg Nm3 157 17 157 22 Sortie fum e mm 80 Prise d air externe mm 60 Combustible Granul s de bois Tirage du conduit de fum e Pa 12 2 Tirage minimum pour dimensionnement du po le Pa 0 0...

Page 114: ...stanza minima da materiali infiammabili X1 X2 Y mm Tensione V V Frequenza f Hz Potenza max assorbita in funzionamento Wmin W Potenza max assorbita in accensione Wmax W Leggere e seguire le istruzioni...

Page 115: ...I01 T04 Pa Pa T03 T02 T01 T05 I03 GND GND GND I04 5V 16V F02 F03 F01 I02 220 240 Vac 20 ext 3 4 ext 1 2 Solo nei modelli con microinterruttori sulla portina o sul coperchio serbatoio Only where micros...

Page 116: ...F02 F03 F01 I02 L 220 240 N 220 240 Vac PE L N BROWN BLUE GREEN RED BLACK BLUE 1 4 t t K 3 ext 1 2 Fig 10 1 Capteur de hall 2 Thermostat externe 3 Sonde ambiante 4 Sonde granul s 5 Sonde fum es 6 Diff...

Page 117: ...nei modelli ventilatore con condensatore Only in models with a condenser room fan Solo nei modelli con microinterruttori sulla portina o sul coperchio serbatoio Only where microswitches are provided...

Page 118: ...ements en bois ou du parquet afin d viter que le poids de l appareil ne les endommage lors de son d placement 5 MANUTENTION ET TRANSPORT L appareil est livr avec toutes les parties pr vues Attention a...

Page 119: ...d de s assurer de leur qualifica tion et de leurs capacit s r elles Pour l Italie ces techniciens doivent poss der une habilitation C remise par la chambre de commerce confor m ment au D cret Minist r...

Page 120: ...d cline toute responsabilit en cas d ventuelles variations des caract ristiques du mat riau composant le plancher sous la protection Pr voir un espace technique acces sible pour les ventuelles interve...

Page 121: ...ig 23 Pr l vement de l air de combustion l ext rieur Dans ce cas il est possible en alternative de canaliser l air de combustion en utilisant un tube d chappement coaxial pour l expulsion des fum es e...

Page 122: ...e et laisser l appareil libre d aspirer l air dans la pi ce en prenant soin de raccorder le tuyau ondul sur le tuyau d entr e d air s il est fourni en le fixant avec le collier et en le pliant l g rem...

Page 123: ...un manque d air de combustion 6 5 Raccord fum e L appareil fonctionne avec la chambre de com bustion sous vide il est donc essentiel de s assu rer que la sortie de fum e est tanche op ration effectuer...

Page 124: ...sortie de l vacua tion des fum es de l appareil il est n cessaire de raccorder un tuyau en bas pour l vacuation de la condensation qui pourrait se former dans la chemin e Fig 26 Fig 26 SEULEMENT POUR...

Page 125: ...en en ce qui concerne les dimensions que pour les mat riaux employ s pour sa construction L vacuation de la fum e par une chemin e tra ditionnelle Fig 28 Fig 29 peut se faire condi tion que la chemin...

Page 126: ...surer que le raccordement la chemin e en ma onnerie est bien scell En cas de passage des tubes tra vers des toits ou des murs en bois il est conseill d utiliser des kits sp ciaux certifi s disponibles...

Page 127: ...S Il est possible d installer le po le de diff rentes mani resenfonctiondesexigencespersonnelles Tube coaxial Tube simple paroi et prise d air dans la pi ce Tube simple paroi et prise d air reli e l e...

Page 128: ...Tube simple paroi et prise d air reli e l ext rieur Dans ce cas l air de combustion sera pr lev directement de l ext rieur l arri re du po le D monter le panneau arri re du po le A D brancher le tuya...

Page 129: ...t possible d installer le po le de diff rentes mani resenfonctiondesexigencespersonnelles Tube simple paroi et prise d air dans la pi ce Tube simple paroi et prise d air reli e l ext rieur 7 3 1 Tube...

Page 130: ...x B Retirer la t le pr coup e C sur le panneau ar ri re A et faire passer le tuyau flexible D pour le raccorder une prise d air externe Fig 37 Serrer le tuyau D avec le collier m tallique E pr c demme...

Page 131: ...le po le est utilis pour chauffer deux ou plusieurs locaux adjacents il est indispensable de favoriser le recyclage de l air ambiant pour uniformiser la temp rature dans les diff rentes pi ces Pour la...

Page 132: ...oir utiliser cette fonction la ventilation des ventilateurs de droite et de gauche doit tre r gl e sur ON Le thermostat qui contr le le ventilateur de droite doit tre connect aux bornes 5 et 6 du born...

Page 133: ...n en ins rant la partie inf rieure de la plaque dans le logement situ sur le support G Fig 44 G A Fig 44 Il est possible de r gler le support H des plaques r fractaires en agissant sur les vis L L H F...

Page 134: ...sistance technique ou par un technicien qualifi afin de pr venir tout risque Fig 48 Il est obligatoire que l installation soit munie d une mise la terre et d un in terrupteur diff rentiel conform ment...

Page 135: ...accord e aux bornes et positionn e sur le panneau arri re Fig 49 Il est possible de positionner la sonde ambiante dans une autre pi ce pour relever la temp rature de l ambiance d sir e Programmer la c...

Page 136: ...a temp ra ture descend en dessous de la valeur d finie sur le thermostat externe circuit ferm Cette configuration peut tre utilis e aussi pour allumer et teindre l appareil manuellement ou de fa on pr...

Page 137: ...bois pellet par chargement automatique 9 2 Premier d marrage Lors du premier allumage du po le veiller ce que les pi ces soient bien ventil es car des odeurs ou des fum es d sagr ables peuvent tre g n...

Page 138: ...s En pr sence de sections horizontales il est n cessaire de v rifier et d liminer les d p ts de cendre et de suie avant qu ils ne bouchent le passage de la fum e En cas de nettoyage inappropri de l a...

Page 139: ...S TOUS LES MOIS Brasero X Tiroir compartiment cendre Fig 57 X Vitre Fig 58 X Grille ventilateur X Chaudi re X 10 3 2Centre d assistance technicien autoris 1 AN Joints porte et brasero X Collecteur de...

Page 140: ...cordon flexible pour nettoyer le conduit d va cuation de la fum e et aspirer les r sidus de cendres A B C Fig 54 10 5 Nettoyage conduit d vacuation de la fum e LINDA US Il est recommand d effectuer l...

Page 141: ...on car les sels contenus provoquent la corrosion du m tal Par ailleurs la cendre pourrait obstruer le passage de l air en modi fiant le d veloppement de la flamme qui pourrait augmenter la corrosion s...

Page 142: ...tergents de d tergents liquides ou de produits agressifs Fig 58 10 8 Nettoyage du collecteur de fum es Apr s avoir bien nettoy le brasero l enlever de son logement et nettoyer le compartiment qui le c...

Page 143: ...animaux un grave danger L limination du produit de mani re diff renci e permet d viter les ventuelles cons quences n gatives pour l environnement et la sant et permet de r cup rer les mat riaux dont i...

Page 144: ...ntial characteristics Palazzetti beh lt sich das Recht vor seine Produkte jederzeit und ohne vorherige Ank ndigung zu ndern um sie zu verbessern ohne ihre grundlegenden Eigenschaften zu beeintr chtige...

Reviews: