Room thermostat for right and left fan control (PRO
3)
It is possible to connect two room thermostats to
the terminal board of the stove so that the right
and left fans can be switched on and off accord-
ing to the temperature set on the thermostats.
To use this function, right and left fan ventilation
must be set to ON.
The thermostat that controls the right fan must
be connected to terminals 5 and 6 of the terminal
board in place of the bridge.
The thermostat that controls the left fan must be
connected to terminals 3 and 4 of the terminal
board in place of the bridge.