
92
004778982 - 09/08/2022
8.2 Configuration 2 - Room thermostat
1
6
1
2
3
4
5
6
22.15 20.3 °C
T
Room temperature
probe
Room
thermostat
Fig. 52
In configuration 2, the appliance is controlled
by an external thermostat (or programmable
thermostat) (not supplied) which switches the
appliance on and off depending on the set tem-
perature (
Fig. 52
).
When the temperature is satisfied, the thermo-
stat opens the circuit and switches off the stove.
The stove switches back on automatically when
the temperature falls below the value set on the
external thermostat (closed circuit).
This configuration can also be used to switch the
appliance on and off manually or in a programmed
way (with the Timer function active); to do this, it
is necessary to remove the jumper between the
two terminals and connect the room thermostat.
If the thermostat allows scheduled pro-
gramming, to avoid overlapping opera-
tion time slots, it is advisable to deacti-
vate the appliance timer by setting it to
OFF.
In this configuration the appliance
switches off when the external thermo-
stat is satisfied.
Summary of Contents for ECOFIRE VIVIENNE
Page 147: ......