7.6.2 PRO 3
B
B
C
C
TA
TA
A
A
Fig. 49
Room thermostat for right and left fan control (PRO 3)
It is possible to connect two room thermostats to
the terminal board of the stove so that the right and
left fans can be switched on and off according to the
temperature set on the thermostats.
To use this function, right and left fan ventilation must
be set to ON.
The thermostat that controls the right fan must be
connected to terminals 5 and 6 of the terminal board
in place of the bridge.
The thermostat that controls the left fan must be
connected to terminals 3 and 4 of the terminal board
in place of the bridge.
7.7 Electrical connection
Simply connect the appliance to the electrical system
using the supplied plug (
Fig. 50
).
The electrical connection (plug) must be easily accessi-
ble after appliance installation as well.
If the power supply cable is damaged it
must be replaced by the technical assis-
tance service or a qualified technician
in order to prevent any risk.
Fig. 50
The system must be equipped with
an earth connection and a differential
switch in compliance with the laws in
force.
The flue gas evacuation duct must be
equipped with its own earth connection.
7.8 Fuel optimisation
Excellent fuel depends on different factors (type of
installation, operating and maintenance conditions,
type of pellets, etc.)
Upon first ignition, the stove can be regulated for opti-
mum combustion performance.
Generally speaking, if at the end of combustion, there
is a lot of residue in the burn pot, you should change
the combustion configuration (by increasing the
value) until you find the best solution.
Refer to function “
(14) Combustion
” of the use and
functionality manual.