84
004778982 - 09/08/2022
• Remove the preform
(E)
on the back panel
(C)
and
insert the flexible hose
(D)
to connect it to an outside
air intake (
Fig. 39
).
• Reassemble the back panel
(C)
and the sides
(A)
and
(B)
by proceeding in reverse order with respect
to what was previously described.
• Connect the flue gas outlet pipe
(F)
(
Fig. 39
).
C
D
E
F
Fig. 39
7.3 Installation configurations VIVIENNE
It is possible to install the stove in different ways ac-
cording to personal requirements:
•
Single-wall pipe and air intake in room
•
Single wall pipe and air intake connected to the out-
side
7.3.1 Single-wall pipe and air intake in room
In this case the combustion air will be taken from the
room.
To achieve this:
• Connect the flue gas outlet pipe
(A)
(
Fig. 40
).
A
Fig. 40
Summary of Contents for ECOFIRE VIVIENNE