ITALIANO
ENGLISH
FRANÇAIS
004778982 - 09/08/2022
81
VIVIENNE - CLELIA TC
1
3
2
Fig. 32
1)
Non-combustible material
2)
Steel piping
3)
Closing panel
7 INSTALLATION
7.1 General considerations
The following sections provide a number of indications
to be complied with in order to obtain the maximum
performance from the purchased product.
The following indications are however
subject to compliance with any possible
national, regional and municipal laws
and regulations in force in the country
where the appliance is installed.
7.2 Installation configurations VIVIENNE US
It is possible to install the stove in different ways ac-
cording to personal requirements:
•
Coaxial pipe
•
Single-wall pipe and air intake in room
•
Single wall pipe and air intake connected to the out-
side
7.2.1 Coaxial pipe
It is possible to use a coaxial pipe to expel the flue
gases and simultaneously recover the combustion air
since the stove has already a factory configuration for
this type of installation.
To achieve this:
• Loosen the screws
(A)
and remove the surface
(B)
(
Fig. 33
).
B
A
A
Fig. 33
• Rotate the surface
(B)
and remove the support
(C)
(
Fig. 34
).
Summary of Contents for ECOFIRE VIVIENNE