33
004778190 - 15/01/2020 - PN - Italy
ENGLISH
CODE
ERROR/WARNING
DESCRIPTION
POSSIBLE CAUSES
LED
E001
Defective control panel
Defectiveness of the control panel
E002
Error of communication with
the remote control
Defectiveness of the control panel
E004
Communication error
Connection cable between board and control
panel interrupted or disconnected
If it appears during the configuration change,
ignore this error
E101
Ignition failure error
Excessively hot supply water
Insufficient pellets
Pellet quality
Faulty ignition system
Dirty burn pot
Problems on the heating system
Circulator problems
E104
Burn pot emptying system
error
Incorrect burn pot positioning
E105
Temperature probe
malfunction
Defective return water probe
E106
Temperature probe
malfunction
Defective puffer probe
E108
Safety error
Loading door or hatch open
E109
Pressure or thermal safety
error
Dirty fume evacuation system
Worn sealing gaskets
Insufficient combustion air
Problems on the heating system
Circulator problems
Problems of overheating of the pellet tank
E110
T e m p e r a t u r e p r o b e
malfunction
Defective supply water probe
Defective air probe
E111
Fume probe malfunction
Defective fume temperature probe
A001
Low pellet level
(flashing icon)
(Where present) Low level of pellets
A002
Scheduled maintenance
notification
(flashing icons)
Periodically, the stove requires maintenance
by a specialist technician
A004
Low spare battery warning
The battery is flat and should therefore be
replaced with a new one
A007
Pressure sensor malfunction
(flashing icon)
Pressure sensor or faults card
----
Stove cleaning
Combustion chamber, burn pot or dirty fume
evacuation
Detached or blocked pressure sensing tubes
Blocked combustion air intake
----
Ignition failure error
Low level of pellets; ignition resistance faulty;
worn seals; Incorrect burn pot position
After checking the message type, it is possible to reset the alarm by pressing the on/off key
for a few seconds.
In case of error ”E109 or E108”, reactivate the manual reset thermostat on the back of the
stove before resetting the alarm.